the
symbols remains on. When the programmed time has
elapsed, the appliance will come on with the previous settings.
Delayed stop: with the appliance on, press the timer button
(F). The
symbol is displayed flashing together with the
hours left before the appliance goes on-standby. Change the
hours using the + and - (C) buttons, then wait a few seconds for
the program to be stored.
The current settings and
At the end of the set time the appliance switches on-standby
automatically. To go back to operating without the timer, press
the timer button twice.
The timer symbol
disappears from the display.
Note: the time is settable from 0.5 to 24 hours.
TROUBLESHOOTING
PROBLEM
The appliance doesn't work
The appliance doesn't work
(the display could blink
and you could hear an
intermittent "beep")
The
display shows
blinking dot and you hear an
intermittend "beep"
The display shows "PF"
The
display shows "Ht"
blincking
(the
heating
power will progressively and
automatically be reduced)
symbol are displayed.
Be sure it is plugged in and that the electrical
outlet is working
The temperature may be set too low
The Key lock may be activated
The air intake or outlet grille is obstructed
a
The appliance could be tipped over or is positioned
in an improper way
The temperature sensor is malfunctioning
The internal temperature is too high
Changing of the temperature scale
The display can show the temperature in both °F (Fahrenheit)
and °C (Celsius). To select the desired temperature scale, when
the unit is in standby position, press and hold the "+" key for at
least 10 seconds, then release.
The change of scale will be indicated by two short beeps.
MAINTENANCE
Before carrying out any maintenance, unplug the heater from
the mains and wait for it to cool off completely. This heater
requires no particular maintenance. It is sufficient to remove
the dust with a soft, dry cloth. Never use abrasive powders or
solvents. If necessary remove concentrated areas of dirt with a
vacuum cleaner.
TECHNICAL CHARACTERISTICS
Power supply
Absorbed power
CAUSE
11
SOLUTION
Plug into the power outlet
Set the temperature to a higher position
See the section "Key lock"
Remove the obstruction remove the plug
from the mains and let the appliance cool
down. After few minutes plug the appliance
again. If the appliance doesn't work please
contact a Customer Experience
Make sure the appliance is standing upright
on a flat surface. Position the appliance
correctly
Contact the nearest customer service
To remove the cause of this alarm check
that the unit is not covered or obstructed.
The appliance will operate again after few
minutes.
Check the appliance is correctly positioned
respecting the minum distances from the wall,
or objects, as indicated on the rating label,
if not, position the appliance correctly. The
appliance will operate again after few minutes.
See rating label
"