■ Examples of Weekly timer
Example 1
7:00
9:00
Monday
Program
Program
to
1
2
Friday
On
Off
26°C
Wake up Leave for
work
Saturday
Sunday
Program
1
Off
(On)
(On)
Example 2: You can specify temperature settings using the On timer in
the Weekly timer.
7:00
9:00
Program 1
Program 2
On
On
28°C
26°C

6.2. On timer or Off timer

1. Select On timer or Off timer in step 2 of "Timer setting
procedure".
(
)
2. Press
to set on time or off time.
Pressing the button: The time will change by +5/-5 minutes.
Pressing down the button: The time will change by +10/-10 minutes.
• To deactivate the On/Off timer, press
shown on the remote controller display.
The indicator will disappear.

6.3. Program timer

1. Set On timer and Off timer. (Refer to "6.2. On timer or Off
timer").
2. Select Program timer in step 2 of "Timer setting procedure".
The timer whose setting time is closer to the current time works first.
The order of the timer operation is displayed as follows:
Timer
Indicator on the remote controller display
On→Off timer
Off→On timer
NOTE:
• You can set the Program timer only within a span of 24 hours.

6.4. Sleep timer

1. Select Sleep timer in step 2 of "Timer setting procedure".
(
)
2. Press
to set the time until the operation
stops.
Each time you press the button, the time changes as follows:
0H
1H
2H
30M
00M
00M
(30 min)
• To deactivate the Sleep timer, press
on the remote controller display.
The indicator will disappear.
During the Sleep timer operation, the setting temperature changes as
the following figure.
In Heating mode
1°C
2°C 3°C
4°C
30 min
1 h
1.5 h
Set time
After the set time has elapsed, the air conditioner operation turns off.
En-7
11:00
17:00
23:00
Program
Program
3
On
28°C
Come back
Go to
home
sleep
(No timer settings)
Program
Program
Program
2
3
Off
Off
(On)
(On)
17:00
23:00
Program 3
Program 4
On
On
27°C
28°C
while
3H
5H
7H
9H
00M
00M
00M
00M
hours
while
is shown
In Cooling or Dry mode
Set time
Set
temperature
1 h
1°C

7. ENERGY SAVING OPERATIONS

7.1. Economy operation

4
It saves more electricity than other operation modes by changing the set
Off
temperature to a moderate setting.
Press
)
operation.
[
] indicator on the indoor unit will turn on.
Operation
mode
4
Cooling/Dry
Few degrees higher than the set temperature
Off
Heating
Few degrees lower than the set temperature
NOTES:
• In the Cooling, Heating, or Dry mode, the maximum output of this
operation is approximately 70 % of usual operation.
• This operation cannot be performed during the temperature
monitoring by the Auto mode.

7.2. Occupancy sensor for energy saving

• Do not use this function when there are only infants,
children, elderly, or sick persons in the room.
• Do not use this function in server rooms or other
is
places where there is no one in the room.
• Do not place large objects near the occupancy sensor.
Also keep heating units outside the sensor's detection
area.
When no one is in the room, the air conditioner operates moderately to
prevent waste of electricity.
(This function is activated at the time of purchase.)
To change the setting, press
)
While the Energy Saving program is activated,
remote controller display will turn on.
NOTES:
• The following operations will override the Energy Saving program.
- Sleep timer operation
- 10˚C Heat operation
• The Energy Saving program may not work when the room
temperature is very different from the set temperature, such as
when immediately after starting the operation.
■ Details on Energy Saving program
Occupancy sensor on the indoor unit detects movement of people.
If there is no one in the room for approximately 20 minutes, the
temperature will be adjusted moderately.
When someone comes back into the room, the air conditioner revert to
the original settings.
Operation
mode
Cooling/Dry
Higher than the set temperature (Max. +2˚C)
Heating
Lower than the set temperature (Max. -4˚C)
Depending on the operating mode (Cooling/ Heating/
Auto
Dry).
2°C
to activate/deactivate the Economy
Room temperature
WARNING
CAUTION
.