SANITIZING SYRUP SYSTEM

To Be Performed By Qualified Personnel Only
The procedure below is for the sanitation of one
syrup circuit at a time. Repeat to sanitize additional
circuits.
Materials Required:
Sanitizing agent such as "Chlor-tergent" (Oakite
products Co.) or "Diversal CX"
(Diversey-Wyandotte Chemical Co.)
An empty, clean syrup tank
Plastic brush or soft cloth
Prepare the solution by dissolving the required
amount of concentrate to supply 200 PPM (parts
per million) available sanitizer in enough water to
flush and sanitize the number of circuits to be
sanitized, usually about 1 gallon per circuit. Water
temperature should be between 75
1. Locate the syrup tank for the circuit to be
sanitized. Remove both quick disconnects from
the syrup tank. Rinse quick disconnects in potable
water.
2. Connect the machine side of the syrup
disconnect to a clean syrup tank filled with the
sanitizing solution.
3. Connect the CO
syrup tank supply hose to the
2
sanitizer filled tank to pressurize.
4. Place a container under the soda valve to be
cleaned. Actuate the valve to flush sanitizing
solution through the syrup circuit. Dispense until
only sanitizer is coming from the valve. Stop
dispensing and allow the solution to remain in the
system for an additional 15 minutes.
5. Remove the dispensing valve nozzle, and pull
out the center mixing baffle.
6. Using plastic brush or soft cloth and sanitizing
solution, scrub the nozzle, mixing baffle, bottom of
dispensing valve, cup lever (if used). Rinse with
potable water.
7. Reassemble mixing baffle and nozzle.
8. Actuate dispensing valve and allow 1/2 gallon of
sanitizer to be dispensed.
9. Remove tank containing sanitizing solution from
system and connect tank containing syrup into
syrup system.
10. Place a container under the soda valve.
Actuate the valve until only syrup is flowing from
Flush sanitizing
0
0
F. and 125
F.
solution from syrup
system.
Residual sanitizing solution left in system could
create a health hazard.
valve.
11. Flush all sanitizer solution from the syrup tank
To avoid personal
injury or property
damage, do NOT remove cover from the
pressurized tank until all pressure has been
released from the tank.
containing it.
October 1993
Page 15
RS100 and RS150