INITIAL START UP

1. Turn on the CO
.
2
2. Set the high pressure regulator (to the
carbonator) to 80-100 PSI.
3. Set the low pressure regulator to 40-50 psi. Set
diet regulator (if used) to 10-15 psi.
4. Turn on the water to the carbonator.
5. Plug in or turn on the carbonator.
6. Purge CO
gas pressure from the carbonator
2
tank once or twice while it is filling by pulling up on
the pressure relief valve on the top of the tank.
7. Sanitize the ice storage system as instructed on
page 13.
8. Turn the key switch to ON.
9. Fill hopper with sanitary ice.
10. Plug the unit's power cord into an electrical
outlet, the lighted sign should come on. Dispense
several containers of ice.
11. Activate soda valves until water is dispensed.
12. Check the primary CO
carbonator, and the secondary CO
syrup.
13. Connect the syrup containers to the soda
system.
14. Activate the soda valves until syrup is
dispensed with the water.
Ice hopper contains parts
that can move at any
time and will cause injury
if hands are in the way.
Do not remove cover
until the unit has been
unplugged from the
electrical power.
gauge for the
2
gauge for the
2
October 1993
15. Leave the unit alone for about a half hour to
cool the cold plate and soda product.
16. While waiting, check all connections for leaks,
repair as required.
17. When cold plate has cooled, adjust each soda
valve for the proper water to syrup ratio.
To remove valve covers:
Pull off upper front panel.
Twist clear ice chute 1/3 turn counterclockwise
and pull down to remove.
Slide ice chute mounting panel forward to
remove from cabinet. Valve covers may now be
removed. Reverse to reassemble when valves
are adjusted.
Note: there is a timer in the control box that will
activate the rotor in the ice bin every two hours.
The amount of time that the rotor turns is
adjustable between one tenth of a second and 4
seconds. The purpose for the timer is to agitate the
ice to keep it from fusing together after long
periods in the bin.
ICE CHUTE
Page 9
RS100 and RS150
TO ACCESS SODA
VALVE COVERS
ICE
CHUTE
MOUNTING
PANEL