NME1850 & FME2400
REMOVAL AND REPLACEMENT: Auger
To Remove the Auger:
Turn off the water to the machine, and unclip the
evaporator drain hose, pull it down and drain the
evaporator into the bin or a container.
1. The top panel must be removed.
2. Remove ice chute cover.
3. Unscrew ice sweep.
4. Loosen band clamp and remove ice chute body.
5. The auger and breaker/bearing may now be
removed as an assembly.
a. Unscrew 4 allen head cap screws holding
breaker to evaporator.
b. Lift up on breaker and remove auger from
evaporator.
BREAKER
AND AUGER
ASSEMBLY
Note: If the
auger is stuck,
the breaker
must be
removed from
the auger.
The breaker
may be
removed from
the auger and
evaporator
without
disturbing the

auger.

a. Unscrew
breaker cover from breaker (left hand threads)
b. Unscrew auger stud from top of auger.
Disconnect electrical
power before beginning
Use care when
removing the auger, it
has very sharp edges.
January 1994
c. Unscrew 4 allen head cap screws holding
breaker to evaporator.
d. Lift up & remove breaker from evaporator.
e. If the auger is stuck use a slide hammer type
puller to pull on the auger at the threaded hole.
The size of that hole is 5/8"-18.
Inspect the auger, the critical areas of the auger
are:
1. The auger body. It should be clean and
shining. Sometimes an auger will appear clean
when wet, but after it is dry it will be seen to be
stained. Scrub the auger with ice machine cleaner
and hot water.
Ice machine cleaner is an acid. Handle it with
extreme care, keep out of the reach of children.
2. The water seal area. Because the auger has
been removed, the water seal will have to be
replaced. Remove the water seal top half from the
auger, and inspect the auger for minerals clean as
required.
Page 26
CAUTION
SLIDE HAMMER
PULLER
THREAD INTO THE
AUGER HERE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nme1850