Removal And Replacement: Auger - Scotsman FME1504R Service Manual

Scotsman fme1504r ice machine: user guide
Table of Contents

Advertisement

REMOVAL AND REPLACEMENT: Auger

To Remove the Auger:
Turn off the water to the machine, and unclip the
evaporator drain hose, pull it down and drain the
evaporator into the bin or a container.
1. The top panel must be removed.
2. The auger and breaker/bearing may now be
removed as an assembly.
a. Unscrew 4 allen head cap screws holding
breaker to evaporator.
b. Lift up on breaker and remove auger from
evaporator.
Note: If the auger is stuck, the breaker must be
removed from the auger.
BREAKER
ASSEMBLY
The breaker may be removed from the auger and
evaporator without disturbing the auger.
a. Unscrew breaker cover from breaker (left hand
threads)
b. Unscrew auger stud from top of auger.
c. Unscrew 4 allen head cap screws holding
breaker to evaporator.
Hazardous Moving
Parts.
Moving auger can cause
personal injury.
Disconnect electrical
power before beginning.
ALLEN
SCREWS
January 2000
NME1254R & FME1504R
d. Use a slide hammer type puller to pull on the
auger at the threaded hole. The size of that hole
is 5/8"-18.
Inspect the auger, the critical areas of the auger
are:
a. The auger body. It should be clean and
shining. Sometimes an auger will appear clean
when wet, but after it is dry it will be seen to be
stained. Scrub the auger with ice machine cleaner
and hot water.
Ice machine cleaner is an acid. Handle it with
extreme care, keep out of the reach of children.
b. The water seal area. Because the auger has
been removed, the water seal will have to be
replaced. Remove the water seal top half from the
auger, and inspect the auger for minerals clean as
required.
Page 29
SLIDE
HAMMER
PULLER

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nme1254r