REMOVAL AND REPLACEMENT: Auger
WARNING
Disconnect electrical power.
Note that the auger has very sharp edges.
To Remove the Auger:
Turn off the water to the machine, and unclip the
evaporator drain hose, pull it down and drain the
evaporator into the bin or a container.
1. The top panel must be removed, or, if that is not
possible, the gearmotor and freezer assembly
must be pulled part of the way out from the
cabinet. To do that:
a. Unclip the electrical wires from the hanger near
the drive motor.
b. Remove the bolt holding the gearmotor plate.
c. Pull the assembly out.
2. The auger and breaker/bearing may now be
removed as an
BREAKER
assembly.
BEARING
ASSEMBLY
a. Unscrew 4
allen head cap
screws holding
breaker to
evaporator.
b. Lift up on
breaker and
remove auger from
evaporator.
Note: If the
auger is stuck,
the breaker must
be removed from
the auger.
The breaker may
be removed from
the auger and
evaporator without
disturbing the auger.
a. Unscrew breaker cover from breaker (left hand
threads)
b. Unscrew auger stud from top of auger.
c. Unscrew 4 allen head cap screws holding
breaker to evaporator.
d. Lift up on breaker to remove from auger.
If the auger is stuck:
Use a slide hammer type puller to pull on the
auger at the threaded hole. The size of that hole
is 5/8"-18.
Inspect the auger, the critical areas of the auger
are:
a. The auger body. It should be clean and
shining. Sometimes an auger will appear clean
when wet, but after it is dry it will be seen to be
stained. Scrub the auger with ice machine cleaner
and hot water.
///////////////////////////WARNING//////////////////////////////
Ice machine cleaner is an acid. Handle it with
extreme care, keep out of reach of children.
//////////////////////////////////////////////////////////////////////////
b. The water seal area. Because the auger has
been removed, the water seal will have to be
replaced. Remove the water seal top half from the
auger, and inspect the auger for minerals clean as
required.
Note: Repeat the above for each evaporator.
THREAD