Final Check List - Scotsman FM2402R Service Manual

Scotsman fm2402r ice machine: user guide
Table of Contents

Advertisement

FM2402R
FOR THE INSTALLER: Final Check List
1. Is the ice system installed
indoors in a location where the
air and water temperatures are
controlled, and where they do
not exceed the design
ROOF
limitations?
HOLES
2. Is there an electrical service
SEALED?
disconnect within sight of the
installed machine? Has the
voltage been checked, and
compared to nameplate
requirements?
3. Have all the plumbing
connections been made and
checked for leaks?
REMOTE
4. Has the machine and bin been
CONDENSER
leveled?
SECURED?
5. Is there a minimum of 6"
POWER
clearance at the rear, left, right
SUPPLY?
and above the machine for
proper service access?
LEVELED?
6. Is the water pressure a
minimum of 20 psig?
7. Has the machine been
secured to the bin?
8. Is there a water shut off valve
installed near the machine?
PLUMBING?
9. Is the remote condenser
installed per local building codes,
and in a place where it has
adequate ventilation and minimal
solar heat gain?
10. Has all shipping material and
literature (inside the front panel)
been removed from the units?
121 Have the remote condenser
and precharged lines been
properly installed?
12. Has the electrical connection
between the icemaker and the
condenser been made?
13. Verify that the master
switches are in the OFF position.
14. Switch on the electrical
15. Refer to Pre-Start instructions, the next page.
power.
December, 1992