FOR THE INSTALLER

Select the Location:
The unit can only be installed indoors
within the limitations described on
page 2.
The ice machine will have to be
connected to the building's
refrigeration system, check to be
sure that the system has enough
extra capacity to handle a minimum
of additional 8,000 BTU's per hour @
0
110
F. liquid line temperature
0
(assume a 0
F. evaporator
temperature).
Storage Bin:
Using a mechanical lift, install the ice
machine onto the top of the storage
bin.
Fasten the ice machine to the bin
using (4) 5/15-18 2.5" cap screws.
Level the assembly by:
a. Turning the leg levelers in or out
on the standard legs.
b. Use shims under the heavy duty
legs of the KLP4.
Locate the Nameplate: The
nameplate is located on the back
panel of the machine, and contains
the electrical characteristics
particular to the unit being installed.
Refrigeration Installation:
The skills of a refrigeration technician
are required to connect the ice
machine to the buildings refrigeration
system.
Notes:
Suction Line and Liquid Line
Stubs are at the back of the
cabinet.
1.5 ounces of the appropriate
refrigerant is in the system as a holding charge.
Be sure there is enough BTU capacity.
Be sure that the liquid connection is NOT in
series with another liquid line valve.
Local Codes must be observed.
A P-trap should be installed where there will be
more than 10' of vertical rise in the suction line.
TYPICAL INSTALLATION: ALLOW ROOM FOR SERVICE ACCESS
January 1997
Page 3
Single System RL
FME1200RL
B90 STORAGE BIN
BX87 BIN
EXTENSION