TO INSTALL: Plumbing
Built In, Gravity Drain Model:
The drain and inlet water tubes must be plumbed
before connecting to the ice machine. All horizontal
runs of drain lines must have a 1/4" per foot fall. An
air gap will likely be required between the ice
machine drain tube and the drain/waste
receptacle. A stand pipe with a trap below it would
be acceptable for the drain/waste receptacle.
Note: Poor draining will cause a high rate of
ice melting in the bin.
Reservoir
Gravity Drain:
1 2
Connect
Drain Hose Here
1. Place ice machine in front of
installed location. Adjust leg levelers to
approximately correct position.
2. Remove kickplate.
3. Route water inlet line, which should
be a 1/4" O.D. copper tube, from wall
through ice machine to the front.
4. Route drain line from wall position
through ice machine to the front. Note:
if using a long horizontal run (more
than 5') the drain should be vented at
back of cabinet.
5. If electrical outlet for ice machine is
behind the cabinet, plug in the ice
machine now.
6. Push ice
Drain Detail Up
machine into
installed position.
Schematic Side View
of Drain System, Use
Began June 1994.
" I.D.
To June 1994
Production
7. Cut off water inlet line at required length.
8. Flush water line. Place flare nut on inlet water
line and flare the end of the copper tube.
9. Attach flare nut to the male flare on the inlet
water valve.
10. Cut off the drain tube to the required length.
11. Connect the drain tube to the drain fitting at the
front of the cabinet. Use hose clamps to secure
tubes to fittings.
On units built after serialn number 735675-12Z -
June 1994: When replacing an exisiting gravity
drain unit where a
the hose must be replaced by one which is a
I.D. Failure to do this may result in a loose
connection and water leak.
Be certain that the
well past the barbs on the drain fitting. If needed to
ease installation, soak the drain hose in hot water
just before connecting to the fitting.
12. Turn on the water supply and check for leaks.
13. Replace the kickplate.
ALL PLUMBING MUST MEET LOCAL CODES
July 1994
Page 7
5
" drain line (hose) was used,
8
1
" I.D. drain hose is pushed up
2
INSTALLATION OF WATER
AND DRAIN
(Recommended)
Shut Off Valve
Drain Connection
Water Inlet Connection
Detail
DC33
1
"
2
Water Filter