Testing Failover And Failback Of The Agile Fusion Manager - HP IBRIX 9300 Administrator's Manual

Table of Contents

Advertisement

[root@x109s1 ~]# ibrix_fm -f
NAME
------ ----------
X109s1 172.16.3.100
Command succeeded!
1 1.
Install a passive agile management console on a second file serving node. In the command,
the -F option forces the overwrite of the new_lvm2_uuid file that was installed with the
IBRIX software. Run the following command on the file serving node:
/ibrix/ibrixinit -tm -C <local_cluster_interface_device>
–v <agile_cluster_VIF_IP> -m <cluster_netmask> -d <cluster_VIF_device> -w 9009
–M passive -F
For example:
[root@x109s3 ibrix]# <install_code_directory>/ibrixinit -tm -C bond0 -v 172.16.3.1
-m 255.255.248.0 -d bond0:0 -V 10.30.83.1 -N 255.255.0.0 -D bond1:0 -w 9009
-M passive -F
NOTE:
fminstance.xml file. Run the following command:
grep –i current
12.
From the active management console, verify that both management consoles are in the cluster:
ibrix_fm -f
For example:
[root@x109s3 ibrix]# ibrix_fm -f
NAME
------
x109s1
x109s3
Command succeeded!
13.
Verify that the newly installed management console is in passive mode:
ibrix_fm –i
For example:
[root@x109s3 ibrix]# ibrix_fm -i
FusionServer: x109s3 (passive, quorum is running)
=============================
Command succeeded
14.
Enable HA on the server hosting the agile management console:
ibrix_server –m
NOTE:
following error:
com.ibrix.ias.model.BusinessException: x467s2 is not associated with any power sources
Use the following command to define the iLO parameters into the IBRIX cluster database:
ibrix_powersrc -a -t ilo -h HOSTNAME -I IPADDR [-u USERNAME -p PASSWORD]
See the installation guide for more information about configuring iLO.

Testing failover and failback of the agile Fusion Manager

Complete the following steps:
108 Migrating to an agile Fusion Manager configuration
IP ADDRESS
Verify that the local agile management console name is in the /etc/ibrix/
/etc/ibrix/fminstance.xml
IP ADDRESS
----------
172.16.3.100
172.16.3.3
If iLO was not previously configured on the server, the command will fail with the
<property name="currentFmName" value="ib50-86"></property>