GAS TYPE
Main Burners
IR Searing Burner
IR Rotisserie burner (40")
IR Rotisserie burner (52")
Burner
Configuration
ACG 40"
2 Main, 1 Sear,
ACG 52"
3 Main, 1 Sear,
Sides: 300mm, Back: 300mm, Below: 300mm and Above: 1200mm
OUTDOOR USE ONLY.
Check your local building codes for the proper installation method of installation.
In the absence of local codes, this unit should be installed in accordance with
AS/NZS 5601 Gas Installation code and SAA Wiring Rules.

GAS SPECIFICATIONS

GAS CONSUMPTION PER BURNER
NATURAL GAS
Pressure 1.0 kPa
Injector Drill Size
#39/2.50mm
#39/2.50mm
#49/1.85mm
#50/1.75mm
TOTAL GAS CONSUMPTION
NATURAL GAS
95.0 MJ/hr
1 Rotisserie
135.6 Mj/hr
2 Rotisserie
CLEARANCES FROM COMBUSTIBLE MATERIALS
ULPG GAS
Pressure 2.75 kPa
GC
(MJ/hr)
26.4
#53/1.50mm
26.4
#53/1.50mm
15.8
#57/1.10mm
15.0
#57/1.10mm
ULPG GAS
105.0Mj/hr
150.0 MJ/hr
9
Injector Drill
GC
Size
(MJ/hr)
30.0
30.0
15.0
15.0
ELECT. RATING
@ 240VAC
2.1 Amps
2.9 Amps