Motor Brush Replacement
795/1095 Motor Brush Removal
NOTE: Replace brushes worn to
Brushes wear differently on each side of motor,
check both sides. Brush Repair Kit 220853 is
available. Spring clip, 110816,
purchased separately.
1. Read General Repair Information; page 4.
2.
Relieve pressure; page 4.
3. Fig. 4. Remove motor shield (90). Remove in-
spection covers (B) and gaskets on each side of
motor.
54
Fig. 7
less than 1/2 in.
4. Fig. 8. Push in 110816 spring clip (A) to release
may be
5. Fig. 8. Loosen terminal screw (D). Pull brush lead
6. Inspect commutator for excessive pitting, burning
A
B
7703B
hooks (B) from brush holder (C). Pull out spring
clip.
(E) away, leaving motor lead (F) in place. Remove
brush (G) and spring (H).
H
G
Fig. 8
or gouging. A black color on commutator is normal.
Have commutator resurfaced by a qualified motor
repair shop if brushes wear too fast.
(Continued on page 12)
A
C
B
E
D
F
01227
11
309251