1. Safety Precaution
1.1. General guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all
parts which have been overheated or damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers,
insulation papers shields are properly installed.
3. After servicing, make the following leakage current checks to prevent the customer from
being exposed to shock hazards.
1.1.1. Leakage current cold check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and
each exposed metallic cabinet part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a return path to the chassis, the
reading should be between 1M
When the exposed metal does not have a return path to the chassis, the reading must be
1
and 5.2M
.
2