Quadra-Fire 41I-ACC-BK Installation Manual

4100i acc wood insert automatic combustion control (acc)

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
4100I ACC WOOD INSERT
AUTOMATIC COMBUSTION
CONTROL (ACC)
MODEL:
41I-ACC-BK
This appliance has been retired.
Service parts pages within have been removed.
For replacement parts, please refer to the individual service parts
list located on the brand websites.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
R
If the information in these instructions is not
followed exactly, a fire could result causing
property damage, personal injury, or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
Do not over fire - If appliance or chimney connector
glows, you are over firing. Over firing will void your
warranty.
Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house
fire.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass and appliance will cause burns.
Do not touch glass until it is cooled
Use leather gloves when reloading fuel
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
appliance.
Alert children and adults to hazards of high
temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
Fire Risk.
For use with solid wood fuel only.
Other fuels may over fire and generate
poisonous gases (i.e. carbon monoxide).
To obtain a French translation of this manual, please contact
your dealer or visit
Pour obtenir une traduction française de ce manuel, s'il vous
plaît contacter votre revendeur ou visitez
7045-910I
WARNING
WARNING
WARNING
NOTE
www.quadrafire.com
www.quadrafire.com
January 10, 2020

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire 41I-ACC-BK

  • Page 1 MODEL: appliance. • Do not over fire - If appliance or chimney connector 41I-ACC-BK glows, you are over firing. Over firing will void your warranty. This appliance has been retired. •...
  • Page 2: Table Of Contents

    M. Altering The Fireplace ..... . .17 N. Zero-Clearance Fireplace ....17 Quadra-Fire is a registered trademark of Hearth & Home Technologies. 7045-910I...
  • Page 3: Important Safety Information

    (UM) 84-HUD and NPFA211 in the U.S.A. and the ULC S628-93 and CAN/CSA-B365 Installation Codes in Canada. The Quadra-Fire 4100i ACC Wood Insert meets the U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2015.
  • Page 4: Mobile Home Approved

    4100 Insert ACC C. Mobile Home Approved WARNING • This appliance is approved for mobile home installations; when not installed in a sleeping room and when an outside Fire Risk. combustion air inlet is provided. Hearth & Home Technologies disclaims any •...
  • Page 5: Getting Started

    4100 Insert ACC Install Guide Getting Started A. Design and Installation Considerations B. Draft Draft is the pressure difference needed to vent appliances CAUTION successfully. When a appliance is drafting successfully, all combustion byproducts are exiting the home through the Check building codes prior to installation.
  • Page 6: Negative Pressure

    4100 Insert ACC C. Negative Pressure WARNING WARNING Fire Risk. Hearth & Home Technologies disclaims any Asphyxiation Risk. responsibility for, and the warranty will be voided • Negative pressure can cause spillage by, the following actions: of combustion fumes, soot and carbon monoxide.
  • Page 7: Install Checklist

    4100 Insert ACC F. Install Checklist ATTENTION INSTALLER: Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjuction with, not instead of, the instructions contained in this installation manual. _________________________________________________________________________________ Customer: ______________________________________________________________________________ Date Installed: ______________________________________________________________________________ Lot / Address:...
  • Page 8: Dimensions And Clearances

    4100 Insert ACC Dimensions and Clearances A. Appliance Dimensions NOTE: Flue Collar size is 6 inch (152mm) diameter 30 in (762mm) 30 in (762mm) 30” [762] 24 in (610mm) 24 in (610mm) 24” [610] 7 in 7 in (179mm) (179mm) 16-1/4 in 16-1/4 in 16-1/4”...
  • Page 9 4100 Insert ACC 11-3/8” [289] 11-3/8 in 11-3/8 in (289mm) (289mm) 21-1/2” [546] 9-1/8” 9-1/8 in 9-1/8 in 21-1/8 in 21-1/8 in 21-1/8” [232] 20-7/8” 21-1/2 in 21-1/2 in 20-7/8 in 20-7/8 in (232mm) (232mm) (538mm) (538mm) [537] [530] 5 in 5 in (547mm) (547mm)
  • Page 10: Clearances To Combustibles

    4100 Insert ACC B. Clearances to Combustibles United States and Canada (UL and ULC) TOP TRIM 32-1/8 in 22-5/8 in (816mm) (575mm) 42-1/8 in (1070mm) Minimum Opening Inches Millimeters Dimensions Height 21-3/4 USA 18-1/8 in (460mm) HEARTH Front Width (Steel CANADA 30-1/4 EXTENSION...
  • Page 11: Alternate Floor Protection Calculation

    4100 Insert ACC C. Alternate Floor Protection Calculation Material Thermal Resistance: R value The R value is a measure of a material’s resistance to heat transfer. R value is convenient when more than one material is used since you can add the R values together, whereas you can not do this for k value.
  • Page 12: Chimney Systems

    4100 Insert ACC Chimney Systems A. Locating Your Appliance & Chimney • Consider the appliance location in order to avoid floor and ceiling attic joists and rafters. Location of the appliance and chimney will affect • Locate termination cap away from trees, adjacent performance.
  • Page 13: Chimney Termination Requirements

    4100 Insert ACC B. Chimney Termination Requirements NOTICE: Locating the appliance in a basement or in a location of considerable air movement can cause Follow manufacturer’s instructions for clearance, intermittent smoke spillage from appliance. Do securing flashing and terminating the chimney (Figure not locate appliance near: 13.1 &...
  • Page 14: Venting Systems

    4100 Insert ACC D. Venting Systems WARNING Chimney Connector: It is also known as flue pipe or stove pipe. It must be Improper installation, adjustment, alteration, service or 6 inches (152mm) minimum diameter stainless steel maintenance can cause injury or property damage. Refer connector pipe.
  • Page 15: Masonry Chimney

    4100 Insert ACC I. Masonry Chimney • An equivalent liner must be a listed chimney liner system or other approved material. This insert conforms with the UL 1482 and ULC S628 • No dilution air is allowed to enter the chimney. (Canada) in all respects, and is approved to UL &...
  • Page 16: Metal Heat Circulating Masonry

    4100 Insert ACC J. Metal Heat Circulating Masonry • No dilution air is allowed to enter the chimney. a. Secure the fireplace damper in the open position. This insert conforms with the safety standard UL-1482 and If this cannot be accomplished, it will be necessary ULC S628 (Canada) in all respects and is approved to UL to remove the damper and ULC safety standards for installation and use within a...
  • Page 17: Ovalizing Round Stainless Steel Liners

    4100 Insert ACC L. Ovalizing Round Stainless Steel Liners N. Zero-Clearance Fireplace Ovalizing round stainless steel liners to accommodate the A permit may be required for installations, final approval is liner passing through the damper region of a fireplace is an contingent of the authority having local jurisdiction.
  • Page 18: Appliance Set-Up

    4100 Insert ACC Appliance Set-Up A. Outside Air Kit Installation A source of air (oxygen) is necessary in order for combustion to take place. Whatever combustion air is consumed by the fire must be replaced. Air is replaced via Outside Air Cover air leakage around windows and under doors.
  • Page 19: Securing Stove Pipe/Liner To Flue Collar

    4100 Insert ACC B. Securing Stove Pipe/Liner to Flue Collar D. Securing Appliance to Stove Pipe/Liner 1. There are 4 already drilled holes in the flue collar 90 1. Once you have the appliance in place and secured, degrees apart. Attach the flue collar to the stove pipe/ reach up through the flue opening and grab the liner.
  • Page 20: Surround & Trim Kit Installation

    4100 Insert ACC E. Surround & Trim Kit Installation F. Blower Cord Installation on Left Side 1. Lay surround face down on a protected surface to The blower cord is shipped on the right side of the prevent scratching. appliance. You may relocate the cord so it is on the left 2.
  • Page 21: Zero Clearance Adjustable Trim Support

    4100 Insert ACC G. Zero Clearance Adjustable Trim Support EXPLODED VIEW OF SCISSORS 2” - 10” Part No. 841-0990, size 9” x 45” and Part No. ADJSPT-12, size 12” x 50” Included in Kit: (1) Trim Top, (1) Trim Front, (2) Trim SCREWS ARE CIRCLED Sides, Double-Sided Tape (already installed) Tools Needed: Phillips Head Screwdriver, Sheet Metal...
  • Page 22: Mobile Home Installation

    4100 Insert ACC Mobile Home Installation You must use a Quadra-Fire Outside Air Kit Part #: Spark Arestor Cap OAK-ACC 1. An outside air inlet must be provided for combustion Storm Collar and must remain clear of leaves, debris, ice and/or Roof Flashing snow.
  • Page 23: Reference Materials

    4100 Insert ACC Reference Materials A. Service and Maintenance Log Date of Service Performed By Description of Service January 10, 2020 7045-910I...
  • Page 24 4100 Insert ACC Date of Service Performed By Description of Service 7045-910I January 10, 2020...
  • Page 25: Accessory List

    4100 Insert ACC B. Accessory List January 10, 2020 7045-910I...
  • Page 26 Hearth & Home Technologies 352 Mountain House Road Halifax, PA 17032 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafi re.com CAUTION DO NOT DISCARD THIS MANUAL •...