Ariston CLAS ONE R 24 Installation And Servicing Instruction page 41

Hide thumbs Also See for CLAS ONE R 24:
Table of Contents

Advertisement

Description
8
SERVICE PARAMETERS
8
0
BOILER STATISTICS-1
8
0
0
Number of diverter valve cycles (n x10) NOT ACTIVE
8
0
1
Time of circulator on (h x 10)
8
0
2
Number of boiler circulator cycles (n x10)
8
0
3
Boiler Life Time (h x 10)
8
0
4
Time of fan ON (h x 10)
8
0
5
Number of fan cycles (n x10)
8
0
6
Number of flame detection in CH (n x10)
8
0
7
Number of flame detection in DHW (n x10)
8
1
BOILER STATISTICS-2
8
1
0
Number of hours burner operating in heater mode (xxh/10)
8
1
1
Number of hours burner operating in hot water mode (xxh/10) NOT ACTIVE
8
1
2
Number of flame separations (nr/10)
8
1
3
Number of ignition cycles (nr/10)
8
1
4
Average length of heating request (minutes)
8
2
BOILER
8
2
1
Fan Status
8
2
2
Fan speed (x100) rpm
8
2
4
Diverter valve position NOT ACTIVE
Modulating Pump (%) NOT ACTIVE
8
2
7
8
2
8
Gas Power (kW)
8
3
BOILER TEMPERTURE
8
3
1
Heating flow temperature (in °C)
8
3
2
Heating backflow temperature (in °C)
8
4
SOLAR & STORAGE
8
4
2
Solar appliance water input temperature
8
5
SERVICE
8
5
0
Months to next maintenance
If setted the boiler will display that is time to call the installer for maintenance
8
5
1
Enable Maintenance advice
8
5
2
Maintenance Warning Reset
to erase the advice for maintenance
8
5
3
2nd Heat Exchanger Clogging State
8
5
4
PCB hardware version
8
5
5
PCB software version
8
6
ERROR LIST
8
6
0
10 last errors
This parameter allows the last 10 boiler errors flagged to be displayed, indicating the day, month and year.
When the parameter is accessed, the errors are displayed listed from ERROR 0 to ERROR 9.
For each error, the following sequence is displayed:
E00 - error number
108 - error code
8
6
1
Error list reset
value
0 = OFF
1 = ON
from 0 to 60 (month)
0 = OFF
1 = ON
Reset? OK= Yes Esc = No
0 = DHW Exchanger OK
1 = Partially Clogged
2 = Very Clogged Please
Replace
from ERROR 0 to ERROR 9
Reset
OK = yes
ESC = no
MAINTENANCE
activated only with the solar kit
connected
24
0
/
41

Advertisement

Table of Contents
loading

Table of Contents