5.11

Electrical wiring

5.12 Notes on safety for the electrical wiring

 The electrical wiring must be carried out with the electrical supply disconnected.
 Electrical wiring must be carried out by qualified personnel and in compliance with the regulations currently in
force in the country of destination. Refer to the wiring diagrams.
 The manufacturer declines all responsibility for modifications or connections different from those shown in the wir-
DANGER
ing diagrams.
 Do not invert the neutral with the phase in the electrical supply line.
 Check that the electrical supply of the burner corresponds to that shown on the identification label and in this manual.
 The burners have been set for intermittent operation. This means they should compulsorily be stopped at least
once every 24 hours to enable the control box to perform checks of its own start-up efficiency. Normally the
boiler's thermostat/pressure switch ensures the stopping of the burner.
If this is not the case, it is necessary to apply in series with L - N a timer switch that turns off the burner at least
once every twenty-four hours. Refer to the wiring diagrams.
 The electrical safety of the device is obtained only when it is correctly connected to an efficient earthing system,
made according to current standards. It is necessary to check this fundamental safety requirement. In the event of
doubt, have the electrical system checked by qualified personnel.
 The electrical system must be suitable for the maximum input power of the device, as indicated on the label and in
the manual, checking in particular that the section of the cables is suitable for the input power of the device.
 For the main power supply of the device from the electricity mains:
- do not use adapters, multiple sockets or extensions;
- use an omnipolar switch, as indicated by the current safety standards.
 Do not touch the device with wet or damp body parts and/or in bare feet.
 Do not pull the electric cables.
Before carrying out any maintenance, cleaning or checking oper-
ations:
Disconnect the electrical supply from the burner
by means of the main system switch.
DANGER
Close the fuel interception tap.
DANGER
Avoid condensate, ice and water leaks from form-
ing.
DANGER
After carrying out maintenance, cleaning or
checking operations, reassemble the cover and
all the safety and protection devices of the burner.

5.12.1 Control box

This operation must be performed with the burner
turned off and mains power disconnected.
DANGER
To remove the control box (Fig. 13) from the burner follow of the
instruction:
 loosen the screw 1), open the protection 2) and remove all
components.
 Remove the coil 3) and loosen the two screws 4).
 Move a little the control box and remove the high voltage
leads.
The control box can be used on burners with or
without a heater. If the heater is damaged, insert
the jumper 7)(Fig. 14) in the control box so that
the burner can work without the heater until the
WARNING
latter is replaced.
20148481
Installation
4
3
4
S8792
NOTE:
the control box is supplied with the jumper 7)(Fig. 14) al-
ready installed.
If the control box is installed on a burner with heater, it is neces-
sary to remove the jumper 7) before replacing the cover.
Connect the heater cables and thermostat as well.
16
GB
2
1
E9153
Fig. 13
7
Fig. 14