CLASSIC OUTDOOR FURNACE • OWNER'S MANUAL

Important Precautionary Information

Be sure to read carefully and understand these precautions before, during and after the installation, operation and
maintenance of the furnace.
NOTE: All operations must be in accordance with local and state
codes which may differ from the information in this manual.
This outdoor furnace is not intended to be the only source of
heat. In the event of a prolonged power failure, a generator
may be used to prevent lines from freezing. Should the outdoor
furnace be left unattended, run out of fuel or require service, an
alternate heating source in the building being heated should
be in place to prevent damage caused by freezing.
This outdoor furnace and/or chimney is not intended or safety
tested to be used or installed in a building where contents of
that building could be damaged or where a financial loss could
occur from smoke, soot, fire or water.
The outdoor furnace vent cap must fit loosely on the vent
opening. Do not force the cap down or try to seal it tightly onto
the vent pipe. Do not extend or restrict the vent pipe or opening.
DO NOT ALLOW THE OUTDOOR FURNACE TO BE PRESSURIZED.
WARNING
REMOVE STRAPPING FROM
VENT BEFORE FILLING
WITH WATER.
Be sure the outdoor furnace is filled with water before firing.
Never fire the outdoor furnace when the water level is more
than 1" (2.5 cm) below the FULL mark on the sight gauge.
MolyArmor 350 must be added before the initial fill (see Water
Quality and Maintenance).
Disconnect the electrical power to the outdoor furnace before
replacing an electrical component.
CAUTION
Vent Cap Must
Fit Loosely
Do not attempt service inside the electrical control panel
without first disconnecting the electrical power at the main
power source.
NOTE: Any electrical installation should be done by a qualified
installer in accordance with applicable codes.
Allow the outdoor furnace to thoroughly cool and completely
clean out the firebox before draining water from the outdoor
furnace. If the water in the outdoor furnace ever boils, be sure
to check the water level and restore to full. If water is added,
the proper level of MolyArmor 350 Corrosion Inhibitor (p/n
2900630) must be maintained.
When cleaning the outdoor furnace, be careful not to spill any
coals.
ALWAYS store ash in a covered non-combustible container.
Maintain the following clearances from combustibles for the
furnace installation:
• 44" (112 cm) from the back
• 12" (30.5 cm) from the sides
• 48" (122 cm) from the front
• 18" (46 cm) from chimney inspection cover
• The foundation must be noncombustible
Do not allow combustible materials (straw, hay or wood) near
the outdoor furnace. Keep the perimeter of the outdoor furnace
clear and clean.