WIRING DIAGRAMS

To Draft Door
Front Light
White
Yellow or Orange
White
60 Watt Max.
Appliance
Connector
Bulb
Access Panel Wiring Schematic
Side
60 Watt Max.
Light
(Appliance Bulb)
White
Connector
Black
Black
2
Black
Relay
1
Red
Connector
Black
Orange
White
Blue, Extra Lead
Green
Ground Lug
From Side
Access Box
WARNING
!
Disconnect power before removing this panel.
AVERTISSEMENT
!
Coupez l'alimentation électrique avant de
retirer ce panneau.
p/n 7000943 Rev. A
Draft Door Solenoid
1 Amp Fuse
1 Amp
(slow blow)
White
Red
White
Green
Spare
Bung
White
Green
Black
Receptacle
Maximum
Load 10 Amp
White
Black
Red
Sensor Wire
White
White
Black
Black
Connector
White
3
Black
Black
4
Red
Black
Red
Black
Auto
Orange
Black
Off
On
© 2020 Central Boiler
WARNING
!
Remove strapping over vent cap before
filling or operating furnace.
AVERTISSEMENT
!
Avant de remplir ou d'utiliser la chauidère,
retirez la bande qui passe par-dessus le
clapet d'aération.
Access Box
Wiring Diagram
Connector
Connector
Sensor
NOTICE
Time
Delayed
INSTRUCTIO NS
Photo
Electric
Eye
Changing the Furnace Operating Temperature
with the Digital Temperature Controller
1. Press the SET button on the temperature controller.
"SP" will appear in the display.
2.
Press SET again. The set value will now be displayed.
The original value is preset at 185˚F (85˚C).
Light
Switch
3.
Press the UP or DOWN buttons until the desired value is reached.
Black
4.
Press SET to save this setting. "SP" will reappear.
The controller will exit the programming mode if the SET and
5.
DOWN buttons are pressed at the same time or if no
buttons are pressed for one minute.
NOTE: When the OUT (output) light on the controller is lit, the
controller is calling for heat.
NOTE: The temperature controller will only allow values between
150˚F and 195˚F (65˚C and 90˚C). (It is not recommended to set
the controller below 165˚F (74˚C). The value set will be the
temperature at which the outdoor furnace's draft door closes.
The draft door will open 10˚F (5˚C) below this value.
CLASSIC OUTDOOR FURNACE • OWNER'S MANUAL
WARNING
!
Disconnect power before
removing this panel.
Power
White
Disconnect
White
On
Red
Orange
Off
Black
White
Black
3 Amp
Green
Green
Blue
Extra
Lead
T o Side
Access
Panel
IM MEDIATE ACTION RE QU IR ED
Add MolyArmor 350 Corrosion Inhibitor IMMEDIATELY
before filling with water.
CLASSIC and PALLET BURNER MODELS
After filling the system, IMMEDIATELY heat the system
water to 185°F and start the pump(s) to circulate water in
the system.
Read the Owner's Manual for more
information about testing the system water
and submitting water samples to be
certain that proper MolyArmor 350 and pH
43
Coupez l'alimentation
électrique avant de retirer
ce panneau.
White
(Neutral)
Black
(Line Voltage)
(From 15 Amp Breaker)
Green
(Ground)
Ground Rod
Kit (p/n 6593)
Recommended
p/n 7000228
NOTICE
ATTENTIO N!
CL 4030 - 1 unit
CL 5036 - 1 unit
CL 6048 - 2 units
Pallet Burner - 3 units
CL 7260 - 4 units
levels are achieved.