Instructions – Parts List
Parts
10:1 PRESIDENT PUMP
Hydra-Cleanr Units
For Mounting on Open 55 Gallon Supply Drum
(Can be wall-mounted with accessory bracket)
Model 206515, Series C
7 MPa, (69 bar, 1000 psi) Maximum Working Pressure
0.7 MPa, (7 bar, 100 psi) Maximum Incoming Air Pressure
D Stainless steel pump and spray valve handle powerful clean
solutions at high pressure.
D Divorced design pump – keeps cleaning solution from fouling air
motor.
D Accumulator reduces line pulses – air charged at the factory.
D Air line lubricator for automatic lubrication of air motor.
D Suction tube has intake filter.
Solution volume and working pressure can be adjusted using a
different tip orifice size and an air regulator. Fan pattern can be
changed to concentrating jet stream using blasting tip.
Read warnings and instructions.
See page 2 for Table of Contents.
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 1996, Graco Inc. is registered to I.S. EN ISO 9001
306817 rev.K
06017B

Advertisement

Table of Contents
loading

Summary of Contents for Graco Hydra-Clean C Series

  • Page 1 Fan pattern can be changed to concentrating jet stream using blasting tip. Read warnings and instructions. See page 2 for Table of Contents. 06017B GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 Copyright 1996, Graco Inc. is registered to I.S. EN ISO 9001...
  • Page 2: Table Of Contents

    D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. D Do not alter or modify this equipment. Use only Graco parts and accessories.
  • Page 3: Warnings

    WARNING INJECTION HAZARD Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause an extremely serious injury, including the need for amputation. Splashing fluid in the eyes or on the skin can also cause a serious injury. D Fluid injected into the skin might look like just a cut, but it is a serious injury.
  • Page 4 WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re- sult in a fire or explosion and serious injury. D Ground the equipment and the object being sprayed. Refer to Grounding on page 5. D If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing immediately.
  • Page 5: Setup

    Provide adequate nents. For assistance in designing a system to suit ventilation. If the area you are cleaning has stored your needs, contact your Graco distributor. Refer to flammable materials. take appropriate precautions Figure 2 for callouts in parentheses.
  • Page 6: Operation

    Operation Pressure Relief Procedure 3. Close the red handled bleed-type master air valve (required in your system) WARNING 4. Unlock the gun trigger safety and trigger the gun to relieve pressure. INJECTION HAZARD Fluid under high pressure can be in- 5.
  • Page 7 Operation WARNING To avoid serious injury, including fluid injection and splashing in the eyes or on the skin, never point the gun at yourself or anyone else. Before Using Prepare cleaning solution as instructed, observing all safety precautions. Pre-mix powered cleaners in a separate bucket of hot water before adding to water in the supply drum.
  • Page 8: Troubleshooting

    Troubleshooting Before servicing this equipment always make sure to WARNING Relieve the pressure. To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Note: Check all possible problems and solutions Pressure Relief Procedure on page 6. before disassembling.
  • Page 9: Service

    Service General 1. Shut off the air supply to the pump and relieve the pressure. Release air pressure in the accumulator See Fig. 2. Check the air line lubricator often and keep by depressing the valve core plunger pin. Discon- it filled with oil.
  • Page 10: Accessories

    Accessories Stainless Steel Spray Tips AIR SUPPLY TO PUMP 476 kPa 680 kPa ORIFICE SPRAY (4.76 bar, 70 PSI) (6.8 bar, 100 psi) SIZE SIZE ANGLE ANGLE 164435 .043 160964 .043 164434 .052 164436 .052 160957 .062 160963 .062 KEY: GPM : Gallons Per Minute CFM : Cubic Feet Per Minute PSI : Pounds Per Square Inch...
  • Page 11 Notes 306817...
  • Page 12: Parts

    Parts Model 206515 President Hydra-Clean Ref. No. 6 06016B 306817...
  • Page 13 Parts Model 206515 President Hydra-Clean Includes items 1–38 Part No. Description Qty. Part No. Description Qty. 165280 BRACKET, pump mounting 205753 SPRAY HOSE; cpld 3/8 npt(m); 207299 SPRAY NOZZLE EXTENSION KIT 3/8 ID; 40’ (12.2 m) Includes items 22a –22d 214847 AIR LINE LUBRICATOR 164017...
  • Page 14: Dimensions

    Dimensions 1/2 npt air inlet 14–3/4” (375 mm) 28–3/16” (715 mm) 06019 Technical Data Air pressure range ..........150 to 850 kPa (1.5 to 8.5 bar, 20 to 120 psi) Air volume requirements .
  • Page 15 Notes 306817...
  • Page 16: Graco Standard Warranty

    Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of non–Graco component parts.