Instructions/Parts
10:1 President Pump
Hydra-Clean
For mounting on open 55 gallon supply drum. May be wall-mounted with accessory
bracket. For professional use only.
Model 6880119, Series C (PTFE Packings)
Model 206515, Series C (Neoprene Packings)
7 MPa, (69 bar, 1000 psi) Maximum Working Pressure
0.7 MPa, (7 bar, 100 psi) Maximum Incoming Air Pressure
Important Safety Instructions
Read all warnings and instructions in this
manual before using the equipment.
Save these instructions.
Stainless steel pump and spray valve handle powerful
clean solutions at high pressure.
Divorced design pump—keeps cleaning solution from
fouling air motor.
Accumulator reduces line pulses—air charged at the
factory.
Air line lubricator for automatic lubrication of air motor.
Suction tube has intake filter.
Solution volume and working pressure can be adjusted
using a different tip orifice size and an air regulator. Fan
pattern can be changed to concentrating jet stream using
blasting tip.
®
Units
306817N
EN

Advertisement

Table of Contents
loading

Summary of Contents for Graco President Hydra-Clean 6880119

  • Page 1 Instructions/Parts 10:1 President Pump ® Hydra-Clean Units 306817N For mounting on open 55 gallon supply drum. May be wall-mounted with accessory bracket. For professional use only. Model 6880119, Series C (PTFE Packings) Model 206515, Series C (Neoprene Packings) 7 MPa, (69 bar, 1000 psi) Maximum Working Pressure 0.7 MPa, (7 bar, 100 psi) Maximum Incoming Air Pressure Important Safety Instructions Read all warnings and instructions in this...
  • Page 2: Table Of Contents

    Shutdown and Care of Unit ....9 Graco Standard Warranty ....16...
  • Page 3: Warnings

    Read all instruction manuals, tags, and labels before operating the equipment. • Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. • Do not alter or modify this equipment. Use only Graco parts and accessories.
  • Page 4 Warnings WARNING SKIN INJECTION HAZARD Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause an extremely serious injury, including the need for amputation. Splashing fluid in the eyes or on the skin can also cause a serious injury.
  • Page 5 Warnings WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. • Ground the equipment and the object being sprayed. See Grounding. •...
  • Page 6: Setup

    . 2 is only a guide to Ground Wire and Clamp. selecting and installing required and optional components. For assistance in designing a system to suit your needs, contact your Graco distributor. Refer to . 2 for callouts in parentheses. 306817N...
  • Page 7: Connect Hoses And Mount Pump

    Setup Connect Hoses and Mount Pump 1. Using Loctite Pipe Sealant, screw the hose stud 3. Close the air ball valve (24), then connect your 1/2 (10) of the suction hose into the pump’s intake ID (min) air supply hose to the 1/2 nptm(f) inlet housing.
  • Page 8: Operation

    Operation Operation Before Using WARNING Prepare cleaning solution as instructed, observing all safety precautions. Pre-mix powered cleaners in a To avoid serious injury, including fluid injection and separate bucket of hot water before adding to water in splashing in the eyes or on the skin, never point the the supply drum.
  • Page 9: Useful Hints

    Operation Useful Hints Shutdown and Care of Unit NOTICE WARNING Do not allow the pump to run dry. It will quickly accel- erate to a high speed, causing damage. If your pump To reduce the risk of serious injury whenever you are is running too fast, stop it immediately and check the instructed to relieve pressure, always follow the fluid supply.
  • Page 10: Troubleshooting

    Troubleshooting Troubleshooting 1. Follow Pressure Relief Procedure, page 8, before checking or repairing the equipment 2. Check all possible problems and causes before disassembling the equipment. Problem Cause Solution Excessive surge at spray nozzle Obstructed spray tip, valve, or hose Clean, clear Cleaning solution supply empty Refill...
  • Page 11: Service

    Service Service necessary. Check the piston and cylinder wall for pitting or scoring. Check the valve seat in the inlet adapter for wear or damage. General 3. Lubricate the piston seal, and reassemble the accumulator. Remount the accumulator on the See F .
  • Page 12: Parts

    Parts Parts . 3: Model 206515 President Hydra-Clean 306817N...
  • Page 13 Parts Parts List for Models 206515 and 6880119 President Hydra-Clean Ref. Part No. Description Qty. Ref. Part No. Description Qty. 102550 STUD, barbed hose; 3/8 npt(m) 18A826 HOSE, coupled, high press, 40 ft (12 m) 158256 UNION, swivel; 1/2 nptf x 3/8 npsm 214847 AIR LINE LUBRICATOR...
  • Page 14: Dimensions

    Dimensions Dimensions 14-3/4 in. 1/2 npt air inlet (375 mm) 28-3/16 in. (715 mm) 306817N...
  • Page 15: Technical Specifications

    Technical Specifications Technical Specifications ® 10:1 President Pump Hydra-Clean Units Metric Air pressure operating range 20 to 120 psi 1.5 to 8.5 bar (150 to 850 kPa) Pump ratio 10:1 Recommended cycle rate for continuous duty 60 cycles per minute, or 3 gpm Pump discharge pressure 1200 psi) 83 bar, 8.3 MPa...
  • Page 16: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.