Other Alarm Visual And Audible Indicators - Kidde K10SCO User Manual

Combination photoelectric smoke & carbon monoxide alarm, with voice
Table of Contents

Advertisement

3. Other Alarm Visual and Audible Indicators

Operational Mode
Normal (standby)
test (button press
when no alarm
condition is present)
smoke or Co Alarm
Memory (unit has
experienced a smoke
or Co alarm event
within the last hour)
smoke Alarm hush
Mode
smoke Alarm hush
Mode Canceled
Co alarm reset
6
Visual Indications
Green LED blinks approx every
30 sec.
• Test: Red LED blinks in sync with
beep pattern.
Red LED will flash every 30 sec.
Red LED flashes 3 times, every
4 sec.
None
None
Audible Indications
• "Push Test Button" when the unit
is powered up, reminding user to
activate the Test Button
• Button press sound
• 3 long beeps, voice "Fire! Fire",
3 long beeps, 4 quick beeps,
voice "Warning, Carbon
Monoxide," 4 quick beeps, single
beep.
After button push, Sounds 3 beeps
when button is pressed. or
"Caution, Carbon Monoxide
previously detected."
After button push,
voice: "Hush Mode Activated."
Smoke alarm pattern stops.
Voice message "Hush Mode
Canceled."
After button push: CO alarm
pattern stops.
Action/Note:
Perform button press once
a week to verify proper
alarm operation.
Push button to clear Alarm
Memory.
This feature is to be used
only when a known alarm
condition, such as smoke
from cooking, activates
the alarm.
After 8-10 minutes, the
voice message will occur.
Unit is confirming if CO is
present or if it experienced
a nuisance situation.
Re-alarm means danger.
Move to fresh air and call
0800 111 999.

Advertisement

Table of Contents
loading

Table of Contents