3. Other Alarm Visual and Audible Indicators
Operational Mode
Normal (standby)
test (button press
when no alarm
condition is present)
smoke or Co Alarm
Memory (unit has
experienced a smoke
or Co alarm event
within the last hour)
smoke Alarm hush
Mode
smoke Alarm hush
Mode Canceled
Co alarm reset
6
Visual Indications
Green LED blinks approx every
30 sec.
• Test: Red LED blinks in sync with
beep pattern.
Red LED will flash every 30 sec.
Red LED flashes 3 times, every
4 sec.
None
None
Audible Indications
• "Push Test Button" when the unit
is powered up, reminding user to
activate the Test Button
• Button press sound
• 3 long beeps, voice "Fire! Fire",
3 long beeps, 4 quick beeps,
voice "Warning, Carbon
Monoxide," 4 quick beeps, single
beep.
After button push, Sounds 3 beeps
when button is pressed. or
"Caution, Carbon Monoxide
previously detected."
After button push,
voice: "Hush Mode Activated."
Smoke alarm pattern stops.
Voice message "Hush Mode
Canceled."
After button push: CO alarm
pattern stops.
Action/Note:
Perform button press once
a week to verify proper
alarm operation.
Push button to clear Alarm
Memory.
This feature is to be used
only when a known alarm
condition, such as smoke
from cooking, activates
the alarm.
After 8-10 minutes, the
voice message will occur.
Unit is confirming if CO is
present or if it experienced
a nuisance situation.
Re-alarm means danger.
Move to fresh air and call
0800 111 999.