Graco 210ES Repair Manual page 22

Electric airless sprayer
Hide thumbs Also See for 210ES:
Table of Contents

Advertisement

Installation
A
18
ti9129a
1. Inspect pressure control before installation to verify
o-ring is installed.
2. Align pressure control wire cap (21) on fluid mani-
fold so opening faces toward motor.
22
o-ring
K
23
B
21
Pressure Control Assembly Replacement
3. Apply loctite to pressure control knob (B) threads.
4. Screw pressure control threads (B) into manifold
and torque to 150 in-lb (17.0 N.m).
Caution
Be careful when tightening pressure control knob that
wires are not pinched between pressure control and
fluid manifold.
5. Tuck wires into pressure control wire cap (21) and
route wires toward cap opening. Feed wires through
housing hole (K).
6. Insert bushing (23) in hole (K).
7. Connect pressure switch connector (A) to control
board (18).
8. Install shroud (12) with screw (13). Install front cover
(32) with two screws (11). (see illustration, page 15).
9. Install toolbox (3) with two screws (5).
10. Install kick stand (66) on 210
.
ES
311990B