Roughing-In (cont.)
NOTICE: All dimensions are nominal. The stud opening tolerance is +1/8" (3
mm)/-0. Carefully measure your fixture before determining enclosure size. Some
shimming between the stud frame and the fixture may be required. If a firewall is
required, rough-in dimensions will have to increase according to the thickness of the
firewall material. Stud opening dimensions must be measured toward the exposed
side of the wall material. Dimensions given in the rough-in information are crucial for
proper installation. Construct the framing and plumbing accurately.

Plan de raccordement

NOTICE: Toutes les dimensions sont nominales. La tolérance de l'ouverture du
montant est de +1/8" (3 mm)/-0. Mesurer soigneusement votre appareil avant d'en
déterminer la taille de son logement. Un calage entre le cadre du montant et
l'appareil sanitaire pourrait être nécessaire. Si un pare-feu est requis, les dimensions
de raccordement devront augmenter en fonction de l'épaisseur du matériau du
pare-feu. Les dimensions d'ouverture des montants doivent être mesurées vers le côté
exposé du matériau du mur. Les dimensions fournies dans le plan du raccordement
sont cruciales pour une bonne installation. Construire le cadre et la plomberie avec
exactitude.
Diagrama de instalación
AVISO: Todas las dimensiones son nominales. La tolerancia para la abertura entre los
postes es de +1/8" (3 mm)/-0. Mida con cuidado el producto antes de determinar las
dimensiones del encajonado. Quizás sea necesario colocar cuñas entre la estructura de
postes de madera y la unidad. Si se requiere una pared resistente al fuego, las
dimensiones del diagrama de instalación deberán aumentar según el grosor del
material resistente al fuego. Las dimensiones de abertura entre los postes se deben
medir por el lado expuesto del material de la pared. Las dimensiones del diagrama
de instalación son cruciales para una correcta instalación. Construya la estructura y
coloque las tuberías con precisión.
1.

Prepare the Site

WARNING: Risk of property damage. The bath must be supported by the
subfloor. The wall surrounds are not designed to hold the bath in place and are
not intended to be load bearing. The support clips must be used to prevent the
bath from lateral movement.
Framing Provisions
WARNING: Risk of property damage. The bath must be supported by the
subfloor. The wall surrounds are not designed to hold the bath in place and are
not intended to be load bearing. The support clips or screws must be used to
prevent the bath from lateral movement.
NOTICE: Risk of product damage. Do not install the bath over open floor joists. The
basin area requires no additional support when the subfloor is level and square with
the stud framing. Install the bath on an adequately supported, level subfloor.
Shimming is required if the subfloor is not level.
Install a level subfloor. Allow clearance for drainage through the floor joists or
slab and to allow convenient plumbing installation.
For shower door installations: Refer to the shower door manufacturer's
instructions for any special framing considerations. It may be appropriate to add
studs for pivot shower door support.