A.O. Smith BFC Cyclone 28 Installation, User And Service Manual page 110

High efficient condensing water heater
Table of Contents

Advertisement

Cable colors:
1
Brown
2
Blue
3
Yelow/Green
4
Black
5
White
6
Grey/Beige
7
Green
Terminal block connections:
Earth
A
N
Neutral
L
Live input of controller
L
Phase input of isolating
1
transformer (primary side)
L
Phase input of isolating
2
transformer (secondary side)
L
Phase input of
3
program-controlled pump
110
Components:
A
Control
B
Flame probe
C
Hot surface igniter
D
Gas control valve
E
Burner earth connection
F
External ON mode switch
G
Program-controlled pump
(max. 100 W)
H
Extra error signal connection
J
Isolating transformer
K
Double-pole isolator
L
Controller O/I switch
M
Display
N
Fan
O
Temperature sensor
(T
- bottom of tank)
2
P
Dummy
Q
Temperature sensor
(T
- top of tank)
1
R
Selection resistor
S
Push button
T
Electrical anodes
U
Signaling for electrical anodes
V
Potentiostat
Terminal block connections:
J2
Power connection for controller
J19
Extra error signal connection
J20
Gas control valve connection
J21
Program-controlled pump
connection
J40
Fan connection
J36
Controller display connection
JP2
Flame probe and hot surface
igniter connection
JP3
Temperature sensor
T
connection
2
JP4
Dummy connection
JP5
Temperature sensor
T
connection
1
JP6
Selection resistor and pressure
switch connection
JP8
Extra ON mode switch connection
F1
Fuse (T 3.15 A - 250 V)
F3
Fuse (T 3.15 A - 250 V)
Installation, Maintenance and Service part

Advertisement

Table of Contents
loading