4. Night Setback Mode

A. In Cooling and DRY
Mode:
(
and )
OI-153-15EG
Operation with the Remote Control Unit (continued)
SET TEMP.
1 HR.
TIMER
ON I /OFF
MODE
ON
FLAP
OFF
FAN SPEED
SET
Night Setback Mode is used for saving energy.
Press the NIGHT SETBACK button while operation.
The
mark appears in the display.
To release the night setback function, press the NIGHT SETBACK button
again.
When the night setback mode is selected, the air conditioner
automatically raises the temperature setting 1°C when 30 minutes
have passed after the selection was made, and then another 1°C after
another 30 minutes have passed, regardless of the indoor
temperature when night setback was selected. This enables you to
save energy without sacrificing comfort. This function is convenient
when gentle cooling is needed.
Setting
temperature
Press the
NIGHT SETBACK
button
C
TEMP.
NIGHT
SETBACK
ACL
1°C
1°C
30 min.
30 min.
Time
15