Removal
WARNING
Read Injection Hazard, page 3; Burn Hazard, page 4
1.
F
. 14. Remove two screws (71) and swing down
IG
cover (130a).
2.
Disconnect pump ON/OFF switch (130f) connector from
control board.
3.
Press in on two retaining tabs on each side of pump
ON/OFF switch (130f) and remove switch from cover.
F
. 14
IG
310893J
Pressure Control
Pump ON/OFF Switch
Installation
1.
2.
3.
Install new pump ON/OFF switch (130f) so tabs of switch
snap into place on inside of cover.
Connect pump ON/OFF switch connector to control
board.
Swing up cover (130a) and secure with two screws (71).