Download Print this page
Miele DA 217-2 Operating And Installation Instructions
Miele DA 217-2 Operating And Installation Instructions

Miele DA 217-2 Operating And Installation Instructions

Ventilation system
Hide thumbs Also See for DA 217-2:

Advertisement

Quick Links

Operating and Installation
Instructions
Ventilation System
DA 217-2
DA 219-2
UV
To prevent accidents
and machine damage,
read these instructions
before
installation or use.
M.-Nr. 05 603 030

Advertisement

loading

Summary of Contents for Miele DA 217-2

  • Page 1 Operating and Installation Instructions Ventilation System DA 217-2 DA 219-2 To prevent accidents and machine damage, read these instructions before installation or use. M.-Nr. 05 603 030...
  • Page 3 Contents IMPORTANT SAFETY INSTRUCTIONS Guide to the appliance Functional description Operation Main power switch ..........11 Turning on the fan .
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS Read these Operating Instructions carefully before installing or using the Ventilation System. This appliance is designed to vent This appliance is intended for cooking smoke and odors only. residential use only. Use the Be certain your appliance is appliance only for its intended properly installed and grounded by purpose.
  • Page 5 Supervise its use by the conditions it may be possible for an elderly or infirm. installation in these applications. Please contact the nearest Miele dealer or the Be careful when preparing a Technical Service Department with flambé beneath the hood.
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS , WARNING - TO REDUCE , WARNING TO REDUCE THE RISK OF INJURY THE RISK OF A RANGE TOP TO PERSONS IN THE EVENT OF A GREASE FIRE: RANGE TOP GREASE FIRE, Never leave surface units OBSERVE THE FOLLOWING: unattended at high settings.
  • Page 7 When installing the hood, follow the an active chimney, dryer vent, vent recommended minimum safety flue, or room ventilating ductwork. Seek distances between a Miele cooktop and professional advice before connecting the hood: an exhaust hood vent to an existing, –...
  • Page 8 Guide to the appliance...
  • Page 9 Guide to the appliance a Chimney extension m Grease filter button The indicator above the grease filter b Chimney button lights when the grease filters need to be cleaned. This button is also c Canopy used: – to reset the grease filter timer after d Control panel cleaning the grease filters (see "Cleaning and Care").
  • Page 10 Functional description The hood offers two modes of operation: Air extraction Recirculation mode The air is drawn in and cleaned by the Air is drawn through the grease filters grease filters and directed outside. and an active charcoal filter. The filtered air is then recirculated back into The hood comes equipped with a the kitchen through a vent at the top of...
  • Page 11 Operation Main power switch Selecting the power level ^ Use the _ controls to select the ^ Press the main power switch to "I". desired power level. The fan and the lighting can now be operated. & = increases the fan speed decreases the fan speed If the appliance is not going to be used for a long period of time (e.g.
  • Page 12 Operation Delayed Shut Down Turning the lighting on/off If odors or smoke remain in the kitchen The overhead lighting can be turned after cooking has been completed, the on and off independently of the fan. Delayed Shut Down feature can be selected to allow the hood to continue running for either 5 or 15 minutes.
  • Page 13 Operation Filter timers Checking the filter timers To check the percentage of time Grease filters already used: A timer monitors the hours of fan operation. The indicator for the grease filter will light after 30 hours of operation. The grease filters must then be cleaned.
  • Page 14 Operation Reprogramming the timers The grease filter timer is preset to 30 hours. This time can be lengthened or shortened to 20, 30, 40 or 50 hours. The indicator for the grease filter and – A time of 20 hours should be one of the _ indicators will flash.
  • Page 15 Operation Reprogramming the charcoal filter timer The active charcoal filter can only be used in recirculation mode and can not The indicator for the charcoal filter and be used to exhaust fumes. one of the _ indicators will flash. The charcoal filter timer is not preset. The lit indicator shows the programmed Before using the hood in recirculation time:...
  • Page 16 Cleaning and Care Stainless steel Before cleaning or servicing the hood, disconnect it from the power Stainless steel surfaces can be cleaned supply by either removing the fuse, using a non-abrasive stainless steel unplugging it from the outlet or cleaner. manually "tripping"...
  • Page 17 Cleaning and Care Grease filters Depending on the detergent, The reusable metal grease filters cleaning the grease filters in a remove solid particles from the vented dishwasher may cause permanent kitchen air (grease, dust, etc). discoloration of the filter surface. Performance of the filter will not be affected by this discoloration.
  • Page 18 Replacement active charcoal filters The indicator light will go out. can be ordered from the ^ If the charcoal filters are replaced Miele Technical Service Department. before the timer has reached its USA 1-800-999-1360 maximum, the charcoal filter button CDN 1-800-565-6435 should be pressed for 6 seconds to Please quote part # 03 284 681.
  • Page 19 Cleaning and Care Changing the light bulbs Before changing the light bulbs, disconnect the hood from the power supply by either removing the fuse, unplugging it, or manually "tripping" the circuit breaker. ^ Carefully swivel the light bulbs downwards and pull them out to the front.
  • Page 20 After Sales Service In the event of a fault which you can not correct yourself please contact the Miele Technical Service Department 1-800-999-1360 techserv@mieleusa.com 1-800-565-6435 service@miele.ca When contacting the Technical Service Department, please quote the model and serial number of your appliance.
  • Page 21 Installation Instructions...
  • Page 23 Caring for the environment Disposal of packing material Disposal of an old appliance The cardboard box and packing Old appliances may contain materials materials protect the appliance during that can be recycled. Please contact shipping. They have been designed to your local recycling authority about the be biodegradable and recyclable.
  • Page 24 Installation accessories...
  • Page 25 Installation accessories 2 recirculation vents (recirculation mode only) 2 protective shields prevent scratches to the chimney 12 large headed screws 5 x 40 mm during installation. for securing the retaining plates and the canopy. 1 protective shield prevents scratches from the canopy (S8 wall anchors included in the during installation.
  • Page 26 Plywood backing ^ Hold retaining plate A against the The majority of the weight of the wall so that the marks are visible installed ventilation system will be through the holes of the plate (see supported by retaining plate A. It "Installation / Retaining plate A").
  • Page 27 If there is any question concerning the electrical connection of this appliance to your power supply, please consult a licensed electrician or call Miele’s Technical Service Department. 1-800-999-1360 1-800-565-6435 WARNING: THIS APPLIANCE MUST BE...
  • Page 28 Appliance dimensions...
  • Page 29 Recirculation ..31 " - 40 " Miele cooking surface and the ....(800 - 1035 mm) bottom of the hood is: DA 219-2 - 22"...
  • Page 30 Appliance dimensions If the standard unit height H is not suitable to the kitchen’s ceiling height, longer optional chimney extensions are available from your Miele dealer or Miele’s Technical Service Department. DA 217-2 Extraction Recirculation Standard unit H 28" - 37 /8"...
  • Page 31 B is greater than 14 " "Appliance dimensions"). This marks (365 mm). the height of the lower rim of the hood. ^ DA 217-2: Drill a " (3 mm) hole on the center line " (18 mm) above the height marked S.
  • Page 32 Installation Retaining plate A ^ Drill two " (3 mm) holes, one at S + 4" (100 mm) and one at S + 16 " (425 mm) on the center line for the retaining plate (see "Appliance dimensions"). ^ Lightly secure retaining plate A into ^ Drill 4 more "...
  • Page 33 Installation Attaching the canopy Retaining plate C ^ Before attaching the canopy the glass light cover must be removed (see "Cleaning and Care"). Retaining plate C should only be used if dimension Y is greater than 14 " (365 mm.) It provides additional ^ Hang the canopy on the angled stability for the chimney extension.
  • Page 34 (see "Air extraction"). ^ Recirculation mode: The non-return flap is not required. ^ DA 217-2: Secure the canopy with a 5 x 40 mm screw. ^ DA 219-2: Secure the canopy with two 5 x 40 mm screws.
  • Page 35 Installation Attaching the motor assembly Electrical connection Before connecting the appliance read the "Warning and Safety Instructions" and the "Electrical data" sections. ^ First loosely screw the two locking nuts onto the threaded bolts on retaining plate A. Leave a gap of "...
  • Page 36 Installation Air extraction exhaust Recirculation connection connection Recirculation mode is used when venting to the outside of the building is not possible. ^ Connect the ductwork to the exhaust ^ Slide the diverter on to the brackets connection using whatever means of plate B.
  • Page 37 Installation Attaching the chimney extension The use of a chimney extension, allows the hood to be installed at various distances from the ceiling. NOTE: The extension must be intalled in relationship to the method of venting; Extraction or Recirculation. ^ Remove the protective foil from chimney extension.
  • Page 38 Installation Attaching the chimney ^ Screw the extension piece firmly to the upper retaining plate using two 3.9 x 7.5 mm screws. ^ Fold the protective shield at the top. ^ Cover the screws with the supplied ^ Remove the adhesive backing from cap covers.
  • Page 39 Installation ^ Secure the chimney to reatining plate A on both sides with two 3.9 x 7.5 mm screws. ^ Remove the protective foil from the canopy. ^ Pull the chimney apart slightly and slide it over the chimney extension. Do this carefully to prevent scatching the two pieces.
  • Page 40 INSTRUCTIONS" to reduce the risk of the appliance. personal injury. Follow all local building – If the exhaust is ducted through an codes when installing the hood. outside wall, a Miele Telescopic Wall Vent can be used.
  • Page 41 Air extraction Condensate trap Important: If the ductwork runs through rooms, ceilings, garages, etc. where temperature variations exist, it may need to be insulated to reduce condensation. In some cases, a condensate trap may also be required to collect and evaporate any condensate which may occur.
  • Page 44 Alteration rights reserved / 1604 M.-Nr. 05 603 030 / 01 This paper was bleached without the use of chlorine.

This manual is also suitable for:

Da 219-2