Emerson Fisher 667 Instruction Manual page 6

Diaphragm actuator sizes 30/30i-76/76i and 87
Hide thumbs Also See for Fisher 667:
Table of Contents

Advertisement

667 Actuator (Size 30/30i - 76/76i and 87)
June 2017
b. For all other size actuators:
D Slowly lower the actuator down onto the valve. As the yoke passes over the end of the valve stem, place the yoke
locknut over the valve stem. (Note: On small size actuators, it may be necessary to remove the indicator disk and
re‐install it while lowering the actuator onto the valve because the disk will not go through the actuator yoke
opening).
D Continue to lower the actuator while guiding the valve stem into the opening in the end of the actuator stem until
the actuator is in place (see figure 4).
D Screw the yoke locknut onto the valve bonnet and tighten the locknut.
4. Do not connect the actuator stem to the valve stem at this time. Whenever the actuator is installed on the valve, it
is recommended that you perform the Bench Set Spring Adjustment procedures below, to verify that the actuator is
still adjusted correctly.
Figure 3. Actuator‐Mounting Components for Size 30/30i through 70/70i Actuators
X1184
SIZE 30 THROUGH 76
6
DIAPHRAGM CASINGS
DIAPHRAGM AND STEM
SHOWN IN DOWN POSITION
LOADING AIR
PRESSURE CONNECTION
TRAVEL INDICATOR DISK
VALVE STEM
YOKE LOCK NUT
YOKE BOSS
DIAMETER
BONNET
TYPICAL VALVE
(REFER TO
VALVE MANUAL)
W6199-1
VENT ASSEMBLY
DIAPHRAGM
PLATE
ACTUATOR SPRING
ACTUATOR STEM
SPRING SEAT
SPRING ADJUSTOR
STEM CONNECTOR
YOKE
INDICATOR SCALE
X1185
MATCH
LINE FOR
ACTUATOR
Instruction Manual
D100310X012
SIZE 30i THROUGH 76i

Advertisement

Table of Contents
loading

Table of Contents