TYPES OF FLUE INSTALLATIONS

Consult the 'Energysaver Space Heater Co-Axial Flue Systems Installation Manual' included with
the 'On Wall' or 'Direct' flue kits for detailed flue installation instructions. Use only Rinnai Flue
components with this appliance.
IMPORTANT
The following configurations are currently available. For alternative configurations contact Rinnai.
DIRECT / EXTENDED
SIDEWAYS
Co-Ax Pipe 900mm #
EXTERNAL WALL
Co-Ax Pipe 900mm #
IN-WALL
Vertical Adaptor Kit §
Co-Ax Pipe 900mm #
UNDER FLOOR
Co-Ax Pipe 900mm #
The Energysaver Heater comes supplied with a standard back cover kit. For 'Sideways' and
'Underfloor' installations, refer to the 'Energysaver Space Heater Co-Axial Flue System Installation
NOTE
Manual' for details of the alternative back cover kit required.
Flue is NOT to be terminated under the floor or in a roof space. 'Down & Out' and vertical 'through
roof' flue installations are permitted ONLY when the flue terminal is located externally.
DO NOT
For horizontal installations including 'Down & Out' flue systems there must be a continuous fall
of at least 2° to the termination point to drain condensate.
WARNING
Flue terminal must be at least 300 mm above the ground in accordance with AS/NZS 5601, Clause
6.9 and Fig. 6.2.
All terminations exceeding a vertical height of 1.5 metres must incorporate a condensate trap.
The 'AIR INTAKE' hose MUST NOT BE CUT OR SHORTENED. For more detailed information refer
to 'Energysaver Space Heater Co-Axial Flue Systems Installation Manual'.
Rinnai
Option A (Direct)
Direct Flue Kit
Components
Direct Flue Kit
Back Cover Set
(see note below)
Option A (Vertical Termination)
Direct Flue Kit
Bend (2 x 45º)
Condensate Trap
Roof Cowl
ESROOFCOWL
Option A (Direct)
Roof Cowl
ESROOFCOWL
Components
Direct Flue Kit
Bend (2 x 45º)
Back Cover Set
(see note below)
Components
ESDFK
Co-Ax Pipe 900mm (Optional) #
ESDFK
ESPIPE900
Components
ESDFK
ESPIPE900
Co-Ax Pipe 900mm #
ESBEND
ESCONDK
Condensate Trap
Components
ESFKITIW
Vertical Adaptor Kit §
Co-Ax Pipe 900mm #
(ESKIT03)
ESPIPE900
ESDFK
ESPIPE900
ESBEND
§ Includes Condensate Trap (ESCONDK)
21

FLUEING

Direct Flue Kit
Direct Flue Kit
Option B (On Wall Termination)
Direct Flue Kit
Bend (2 x 45º)
Option B (Offset)
Bend (2 x 45º)
Roof Cowl
# Order lengths as required
ESDFK
ESPIPE90
ESDFK
ESPIPE900
ESBEND
ESCONDK
ESFKITIW
(ESKIT03)
ESPIPE900
ESBEND
ESROOFCOWL
ES_FDT3 OIM