Mitsubishi Electric MSC-A07WV-E1 Service Manual page 99

Split-type, air conditioners; split-type, heat pump air conditioners
Table of Contents

Advertisement

1
COOL
200
HEAT
160
Capacity code
1
Indoor unit
07
<Correction>
1 Suction super heat
(MIN gas pipe temperature thermistor - Evaporation temperature thermistor)
2 Each correction w 1
• (Each gas pipe temperature thermistor - Evaporation temperature thermistor)
3 Discharge temperature
w 1 Perform this, when number of operation units is 2 units or more.
w 2 When the correction opening of suction super heat is 0, correct the LEV opening by discharge temperature.
(1) LEV opening correction by suction super heat (COOL, DRY)
(Suction super heat) = (Minimum gas pipe temperature) - (Evaporation temperature)
When COOL and DRY, correct the LEV openings corrected from the table below.
Suction superheat (S.H.) LEV opening
more than 12
10 to12
8 to 10
6 to 8
6 or less
(2) Separate correction (COOL,DRY)
(When number of operation unit is 2 units)
(a) Correction by the separate super heat
Correct the LEV separately by temperature difference between each gas pipe temperature thermistor and evaporator
temperature thermistor.
1 Calculate each super heat of the unit from the expression below;
(Super heat) = (Each gas pipe temperature) - (Minimum gas pipe temperature)
2 Separate correction is performed according to each super heat in the table below.
LEV opening
Superheat
correction (pulse)
more than 9
6 to9
3to 6
6 or less
All manuals and user guides at all-guides.com
Standard opening (pulse)
2
3
4
5
6
210
220
230
240
240
170
180
190
200
210
2
3
4
09
12
18
correction (pulse)
7
5
4
3
0
10
8
4
0
Difference in
capacity
7
8
Code2
Code3
250
250
25
210
220
20
COOL
99
Difference in
operation number
2
50
-60
40
-70
DRY
HEAT
-
w 2
w 2