Appendix 1 Main differences with the FR-E500(N) CC-Link model

Item
Control method
Shape
Connectable units
Station type
Number of occupied
stations
Connection cable
Station number
setting
Transmission baud
rate setting
Communication by
the 24V external
power supply
Changed/cleared functions
Inrush current limit circuit
Terminal block
specification
Input terminal
Output terminal
Operation panel
Parameter unit
RS-485 communication
Option unit
Installation size
274
FR-E500 (N)
V/F control
General-purpose magnetic flux vector control
Terminal block connection (removable from the
inverter front)
Up to 42 units (one unit occupies one station). Other
models can also be used.
One inverter occupies one station.
CC-Link dedicated cable, CC-Link Ver. 1.10 compatible CC-Link dedicated cable
Set with the rotary switch
Set with the rotary switch
Not available
Torque boost (Pr. 0) initial value
FR-E520-1.5KNC to 7.5KNC: 6%
DC injection brake operation voltage (Pr. 12) initial
value
0.4K to 7.5K: 6%
Second electronic thermal O/L relay (Pr. 48)
Shortest acceleration/ deceleration mode (Pr. 60)
Second applied motor
Pr. 71 = 100 to 123
Operation mode selection (Pr. 79 )
Initial value 2: CC-Link operation mode
Setting range: 0 to 2
Setting General-purpose magnetic flux vector
Pr. 80 ≠ 9999
User group 1 (16), user group 2 (16)
(Pr. 160, Pr. 173 to Pr. 175 )
Input terminal function selection (Pr. 180 to Pr. 183 )
setting
6: MRS signal (output stop)
Cooling fan operation selection (Pr. 244 ) initial
setting
0: Cooling fan operates in power-on status.
Stop selection (Pr. 250 ) setting increments
1s
Provided for the 2.2K or higher
Fixed terminal block (cannot be removed)
Screw type terminal block (Phillips screw M2.5)
Length of recommended blade terminal is 7mm
MRS (can be assigned), RES (can be assigned)
ABC (can be assigned), relay output
Not available
FR-PU04
Available
FR-HC and FR-CV are connectable.
V/F control
General-purpose magnetic flux vector control
Advanced magnetic flux vector control
Optimum excitation control
Two one-touch connectors dedicated to CC-Link
communication
Up to 42 units. (Refer to page 105 for the number of
occupied stations). Other models can also be used.
Remote device station
CC-Link Ver. 1: Occupies one station.
CC-Link Ver. 2: Occupies one station (double,
quadruple, and octuple settings are selectable). (Pr.
544)
Set with the parameter (Pr. 542)
Set with the parameter (Pr. 543)
Available
FR-E720-1.5KNC to 3.7KNC: 4%
FR-E720-5.5KNC, 7.5KNC: 3%
0.4K to 7.5K: 4%
Parameter numbers changed
(Pr. 51 Second electronic thermal O/L relay)
(Pr. 60 Energy saving control selection)
(Pr. 292 Automatic acceleration/deceleration)
Pr. 450 Second applied motor
Initial value 0: CC-Link operation mode is selected at
Setting range: 0 to 4,6,7
Pr. 80 ≠ 9999, Pr. 81 ≠ 9999, Pr. 800 = 30
User group (16) only, setting methods were partially
changed
(Pr. 160, Pr. 172, Pr. 173 )
Pr. 180 to Pr. 184 Input terminal function selection setting
6: None
24: MRS signal (output stop)
1: Cooling fan on/off control valid
0.1s
Provided for the all capacity
Removable terminal block
Spring clamp terminal block (The spring pressure
inside locks the wire.)
Length of recommended blade terminal is 10mm
S1 and S2 (cannot be assigned)
Y0 (can be assigned), open collector output
Integrated operation panel (can not be removed)
Cannot be used
Not available
FR-HC and FR-CV are not connectable (because FR-
E700-NC do not have the terminal MRS.)
Installation size is compatible
FR-E700 (NC)
power ON