Mitsubishi Electric FR-E720-0.1KNC Instruction Manual page 121

Table of Contents

Advertisement

Adjustment of the output torque (current) of the motor
<Selection method of General-purpose magnetic flux vector control>
Mitsubishi standard
motor
Mitsubishi high
efficiency motor
Mitsubishi constant-
torque motor
Other manufacturer's
standard motor
Other manufacturer's
constant-torque
motor
∗1
Refer to page 144, for other settings of Pr. 71.
∗2
Refer to page 146 for offline auto tuning.
Set the motor capacity and the number of motor poles.
Select the control method.(Pr. 800) (Refer to page 117)
Set the operation command. (Refer to page 103)
As required
Perform offline auto tuning. (Pr. 96) (Refer to page 146)
Set slip compensation. (Pr. 245, Pr. 246, Pr. 247) (Refer to page 119)
NOTE
Uneven rotation slightly increases as compared to the V/F control. (It is not suitable for machines such as grinding
machine and wrapping machine which requires less uneven rotation at low speed.
When a surge voltage suppression filter (FR-ASF-H/FR-BMF-H) is connected between the inverter and motor, output
torque may decrease.)
Parameters referred to
Pr.3 Base frequency, Pr.19 Base frequency voltage
Pr.71 Applied motor
Pr.77 Parameter write selection
118
Perform secure wiring.
(Refer to page 14)
Set the motor.(Pr. 71)
Motor
SF-JR
SF-HR
Others
SF-JRCA 4P
SF-HRCA
Others (SF-JRC, etc.)
(Pr. 80, Pr. 81) (Refer to page 117)
Set motor capacity (kW) in Pr. 80 Motor capacity and
the number of motor poles (number of poles) in Pr. 81 Number of motor poles.
(V/F control is performed when the setting is "9999" (initial value).
Set "30" in Pr. 800 to make General-purpose magnetic flux vector control valid.
Select the start command and speed command.
(1)Start command
(2)Speed command
Test run
Refer to page 144
Refer to page 196
Pr. 71 Setting ∗1
0 (initial value)
40
3
1
50
13
3
13
1)Operation panel: Setting by pressing
2)Command via CC-Link communication: Setting with the forward or reverse
rotation command (STF or STR signal)
1)Frequency command via CC-Link communication
2)Operation panel: Setting by turning
3)Multi-speed command:
The RH, RM, and RL signals transmitted via CC-Link communication can
be also used as speed commands.
Refer to page 126
Remarks
Offline auto tuning is necessary.
Offline auto tuning is necessary.
Offline auto tuning is necessary.
Offline auto tuning is necessary.
on the operation panel
on the operation panel
∗2
∗2
∗2
∗2