WARNING
If you supply your own hoses and spray gun, be
sure the hoses are electrically conductive, that the
gun has a tip guard, and that each part is rated for
at least 3000 psi (210 bar , 21 MPa) Working Pres -
sure . This is to reduce the risk of serious injury
caused by static sparking, fluid injection or over-
pressurization and rupture of the hose or gun.
CAUTION
To avoid damaging the pressure control, which may
result in poor equipment performance and compo-
nent damage, follow these precautions:
1. Always use a nylon spray hose at least 15 m
long.
2. Never use a wire braid hose as it is too rigid to
act as a pulsation dampener.
3. Never install any shutoff device between the filter
and the hose. See Fig. 4.
1. Plug the power cord (50) into the inlet receptacle
located below the motor. Tighten the screws (A) of
the cord wire clamp (65) securely. See Fig 2. If the
power cord you are using does not have a male
plug attached, have a qualified electrician install an
appropriate plug.
A
Fig. 2
2. Connect the hose (74) and gun (67) and screw it
onto the outlet nipple (E). Don't use thread sealant,
and don't install the spray tip yet!

Setup

3. Fill the wet–cup (102). Pry off the wet-cup seal.
4. Check the electrical service. It must be 110 Vac,
5. Plug in the sprayer. Be sure the ON/OFF switch
50
6. Flush the pump to remove the lightweight oil
65
7. Prepare the paint according to the manufacturer's
Fill the cup 1/3 full with Graco Throat Seal Liquid
(TSL), supplied. Install the wet-cup seal.
50 Hz, 10A (minimum). Have a licensed electrician
attach an appropriate plug, with a grounding prong,
to the power supply cord. Do not remove the
grounding prong and do not use an adapter.
You may use a 3-wire, 1.0 mm
mum) extension cord up to 45 m long.
WARNING
FIRE AND EXPLOSION HAZARD
Proper electrical grounding is essential
to reduce the risk of fire or explosion
which can result in serious injury and
property damage. Also read FIRE OR
EXPLOSION HAZARD on page 2
(52) is OFF. Plug the cord into a grounded outlet at
least 6 m away from the spray area.
Fig. 3
which was left in to protect pump parts after fac-
tory testing. See page 13.
recommendations. Remove any paint skin. Strain
the paint through a fine nylon mesh bag (available
at most paint dealers) to remove particles that
could clog the spray tip. This is an important step
toward trouble-free paint spraying.
2