Figure A-5 Method B.1 (Quick Term) For Shield Termination - Garmin GTR 200B Installation Manual

Com transceiver
Hide thumbs Also See for GTR 200B:
Table of Contents

Advertisement

Connect a Flat Braid (item 4, Figure A-5) to the folded back shield of the prepared cable assembly.
The flat braid should go out the front of the termination towards the connector. It is not permitted
to exit the rear of the termination and loop back towards the connector (Figure A-5). Make this
connection using an approved shield termination technique.
NOTE
FAA AC 43.13-1B Chapter 11, Section 8 (Wiring Installation Inspection Requirements)
may be a helpful reference for termination techniques.
Preferred Method:
Slide a solder sleeve (item 3, Figure A-5) onto the prepared cable assembly and connect the Flat Braid
(item 4, Figure A-5) to the shield using a heat gun approved for use with solder sleeves. It may prove
beneficial to use a solder sleeve with a pre-installed Flat Braid versus having to cut a length of Flat
Braid to be used. The chosen size of solder sleeve must accommodate both the number of conductors
present in the cable and the Flat Braid (item 4, Figure A-5) to be attached.
NOTE
Reference
Section A.2
recommendations are applicable to this technique.
Secondary Method:
Solder a Flat Braid (item 4, Figure A-5) to the folded back shield on the prepared cable assembly.
Ensure a solid electrical connection through the use of acceptable soldering practices. Use care to
avoid applying excessive heat that burns through the insulation of the center conductors and shorts the
shield to the signal wire. Slide a minimum of 0.75 inches of Teflon heat shrinkable tubing onto the
prepared wire assembly and shrink using a heat gun. The chosen size of heat shrinkage tubing must
accommodate both the number of conductors present in the cable as well as the Flat Braid (item 4,
Figure A-5) to be attached.
Teflon Heat Shrinkable Tubing:
Reference the following MIL-Spec for general Teflon heat shrinkable tubing (M23053/5-X-Y)

Figure A-5 Method B.1 (Quick Term) for Shield Termination

190-01553-00
Rev. P
for recommended solder sleeves and flat braid. The same
GTR 200/200B Installation Manual
Page A-8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gtr 200

Table of Contents