Dimplex SOLCU3 Installation And Operating Instructions Manual page 74

Temperature difference controller 6 inputs, 3 outputs, integrated data logger for sd card, solar controller
Table of Contents

Advertisement

7.3.10 Time function
This function allows a controller output to be controlled depending on
a predefined time range.
Setting the time window
"Functions" submenu selected, see "Selecting a function"
(see chapter 7.3.1).
Time function activated, see "Activating a function"
(see chapter 7.3.1).
Outputs selected, see "Selecting an output" (see chapter 7.3.1).
: press button.
The display for setting the duration appears.
SET: press button.
The time value flashes in the display.
: set the time value.
SET: confirm the value and go to the next value.
The settings are saved.
NOTE
The switch-on time must always be before the switch-off time. There-
fore, when the switch-on value is being adjusted, the switch-off value
will also be changed to a later time if necessary. Adjusting the switch-off
value to a time before the switch-on value is blocked.
7.3.11 Interval function
With some types of collector, the collector's construction does not allow
the temperature to be recorded at the appropriate location. In these
cases, the solar circuit must be briefly activated at regular intervals to
transmit the actual heat from the collector pipe to the collector sen-
sor. When the interval function is activated, the controller automatically
switches the pump on according to the settings.
Setting the interval function
"Functions" submenu selected, see "Selecting a function"
(see chapter 7.3.1).
Interval activated, see "Activating a function" (see chapter 7.3.1).
: press button.
The display for setting a time window, the interval time, and the
test time appears.
SET: press button.
The time window's start time flashes in the display.
: set the start time.
SET: confirm the value and go to the next value.
After confirmation of the time window, the "Interval" duration
(the time between the tests) flashes.
: set the interval duration.
SET: press button to confirm.
After confirmation of the "Interval" duration, the "Test" duration
(duration for which the pump is switched on) flashes.
: set the test duration.
74
EN
 
[.......................]
[.......................]
Display: 3.9
Display: 3.9
[Time function]
[Time function]
 
Display: 3.9.3
Display: 3.9.3
 
[...........]
[...........]
Display: 3.10
Display: 3.10
[Interval]
[Interval]
 
[.........]
[.........]
[.........]
[.........]
Display: 3.10.
Display: 3.10.
[Interval]
[Interval]
[Test]
[Test]
730.137 | 08.37
on-off
on-off
/
/
T
T
08:00 - 19:00
08:00 - 19:00
15 min
15 min
10 s
10 s

Advertisement

Table of Contents
loading

This manual is also suitable for: