Before Calling for Service

Check the following:
1. Has the water supply to the ice machine or building been shut off? If it has, the ice machine will
automatically restart within 25 minutes after water begins to flow to it.
2. Has power been shut off to the ice machine? If yes, the ice machine will automatically restart when
power is restored.
To Manually Reset the machine:
1. Remove the front panel.
2. Locate the AutoIQ Controller. If a red diagnostic light is glowing, note which one and its blink rate.
Then push and release the off button.
3. Push and release the Freeze button.
4. The machine should begin to operate. If there is a
lack of water it will shut off again soon.
5. Return the front panel to its normal position.
If the machine shuts down again, call for service.
To Shut the Machine Off:
1. Remove the front panel.
2. Locate the controller.
3. Push and hold the Off button for 3 seconds or until
the machine stops.
CME256, 506, 656, 806: AutoIQ Cubers
7