REFRIGERANT METERING DEVICE:
capillary tube
REFRIGERANT CHARGE (R 404 A)
air cooled
AFC 134
380 gr
NOTE. Before charging the refrigerant system
always check the type of refrigerant and
quantity as specified on the individual ice
machine dataplate.
The refrigerant charges indicated are relatives
to averages operating conditions.
Discharge pressure:
water cooled
Air cooled version
300 gr
Water cooled version
Suction pressure:

OPERATING PRESSURES

°
(With 21
C ambient temperature)
Page 16
17 ÷ 18 bar
245 ÷ 260 psig
17 bar
245 psig
2.9 bar
42 psig