3. Cooling Mode Operation
• When selecting the Cooling(
controller and the operation diagram is as following
Intake Air temp.
COMP. ON
(SET TEMP.+0.5°C)
COMP. OFF
(SET TEMP. -0.5°C)
INDOOR FAN
COMPRESSOR
4. Cooling or Heating Mode with Sleep Mode Auto Operation
• When selecting the Cooling(
operation diagram is as following.
■ Cooling Mode with the Sleep Mode
• The setting temperature will be raised by 1°C 30minutes later and by 2°C 1 hour later.
• The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
Intake Air temp.
COMP. ON
(SET TEMP.+0.5°C)
COMP. OFF
(SET TEMP. -0.5°C)
INDOOR FAN
COMPRESSOR
■ Heating Mode with the Sleep Mode.
• The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
Setting Temp. +3°C
(Compressor OFF)
Setting Temp.
(Compressor ON)
Indoor Fan
Compressor
) Mode Operation, the unit will operate according to the setting by the remote
More than
3 minutes
Selecting
Low
fan speed
ON
OFF
) or the Heating(
30 minutes
More than
3 minutes
Low
Low
ON
OFF
Med.
Med.
ON
OFF
Selecting
fan speed
ON
) combined with the Sleep Mode Auto Operation(
1°C
More than
3 minutes
Low
Low
ON
OFF
Med.
Med.
ON
OFF
–11–
More than
3 minutes
Selecting
Low
fan speed
OFF
ON
30 minutes
1°C
Low
ON
Med.
Med.
ON
OFF
), the

Advertisement