Thermostat Chart - Single Stage Heat Pump With Two Stage Variable Speed Furnace (Hot Heat Pump Or Conventional) - Johnson Controls TM8V MP Series Installation Manual

Residential gas furnace
Table of Contents

Advertisement

523353-UIM-B-0210
HP 15A
Single Stage Heat Pump – Two Stage Variable Speed Furnace (Hot Heat Pump or Conventional)
THERMOSTAT
THERMOSTAT
*BP21H50124
*BN21H00124
*DN22U00124
*DP21H40124
*DN21H00124
C
24 – Volt Common
24 – Volt Common
Y
First Stage Compressor
First Stage Compressor
R
24 – Volt Hot
(Heat XFMR)
G
Fan
E
Emergency Heat
Emergency Heat
RC
24 – Volt Hot
(Cool XFMR)
O/B
Reversing Valve
Reversing Valve
Energized in Cool
L
Malfunction Light
Malfunction Light
AUX
Auxiliary Heat
Second Stage Heat
Thermostat Installer Setup
B/O Switch on Thermostat
1-System Type-must be set
must be in the O position
to 5 – 2 Heat/1 Heat Pump
Thermostat Installer Setup
2-Changeover Valve-must
be set to 0 – O/B terminal
Energized in Cooling
FIGURE 18: Thermostat Chart - Single Stage Heat Pump with Two Stage Variable Speed Furnace (Hot Heat Pump or Conventional)
14
THERMOSTAT
*DP32H70124
C
C
24 – Volt Common
Y1
Y1
First Stage Compressor
R
R
24 – Volt Hot
24 – Volt Hot
G
G
Fan
Fan
E
E
Emergency Heat
W2
Third Stage Heat
O
O
Reversing Valve
Energized in Cool
L
L
Malfunction Light
Y2
Y2
Second Stage
Second Stage
Compressor
Compressor
W1
W2
Second Stage
Aux. Heat
24VAC Humidifier
(Optional)
3
External Humidistat
(Optional)
Open on Humidity Rise
3
External Humidistat
(Optional)
Open on Humidity Rise
Step 1 of Thermostat
Installer / Configuration
Menu must be set to
Heat Pump 1
Part Number:
3
S1-2HU16700124
ID MODELS
PV(8/9)
(F/L)*(8/9)V
(G/L)*(8/9)V
TM(8/9)V
TWO STAGE
VARIABLE SPEED
FURNACE
TWO STAGE
2
VARIABLE SPEED
FURNACE CONTROL
C
24 – Volt Common
Y1
Single Stage
Compressor
R
24 – Volt Hot
G
Fan
W/W1
First Stage Heat
W2
Second Stage Heat
Y/Y2
Second or Full
Stage Compressor
O
Reversing Valve
X/L
Malfunction Light
DHUM
Dehumidification
Bonnet Sensor Kit
(Optional)
S1-37309243000
Move HEAT PUMP
jumper to "YES"
Move DHUM
jumper to "YES"
if humidistat is to be used.
Part Numbers:
2
SAP =
Legacy
265904 = 031-09169
449572
Johnson Controls Unitary Products
OD MODELS
YZB
YMB
H*3
SINGLE STAGE
HEAT PUMP
1
YORKGUARD VI
CONTROL
C
24 – Volt Common
Y1
Single Stage
Compressor
R
24 – Volt Hot
W1 OUT
First Stage Heat
W2 OUT
Second Stage Heat
Y2 OUT
Second Stage
Compressor
O
Reversing Valve
Energized in Cool
X/L
Malfunction Light
Y2
Second Stage
Compressor
W
Auxiliary Heat
BSG
Bonnet Sensor
BS
Bonnet Sensor
Change FFuel jumper
on the heat pump control
to "ON"
Change Hot Heat Pump
jumper on the heat pump
control to "ON" if Hot Heat
Pump Operation is desired.
Part Numbers:
1
SAP =
Legacy
126768 = 031-09137