Introduction; Initial Inspection; Lcr; Power Cable - HP 4262A Operating And Service Manual

Digital lcr meter
Hide thumbs Also See for 4262A:
Table of Contents

Advertisement

Model 4262A
Section 1I
Paragraphs 2-1 to 2-11
SECTION
11
INSTALLATION
2-1.
INTRODUCTION.
2-2. This section provides installation instructions
for the Model
4262A
LCR
Meter. The section also
includes
information
on
initial
inspection
and
damage
claims,
preparation
for using the 4262A,
packaging, storage, and shipment.
2-3. INITIAL INSPECTION.
2-4.
The
4262A
LCR
Meter, as shipped from the
factory, meets all the specifications listed in Table
1-1. On receipt, inspect the shipping container for
damage.
If the
shipping
container
or
cushioning
material
is damaged,
notify
the carrier as well as
the Hewlett-Packard
office and be sure to keep the
shipping materials for carrier's inspection until the
contents
of the shipment
have
been
checked
for
completeness
and the instrument has been checked
mechanically
and electrically. The contents of the
shipment
should be as shown
in Figure 1-1. The
procedures
for checking
the general
electrical op-
eration are given in Section III (Paragraph 3-5 Ba-
sic
Operating
Check)
and
the
procedures
for
checking the 4262A
LCR
Meter against its specifi-
cations are given in Section IV, Firstly, do the self
test. If the 4262A LCR Meter is electrically ques-
tionable,
then do
the Performance Tests to deter-
mine whether the 4262A has failed or not. If con-
tents are incomplete, if there is mechanical damage
or defects (scratches, dents, broken switches, etc.),
or if the performance does not meet the self test or
performance
tests,
notify
the
nearest
Hewlett-
Packard office (see list at back of this manual). The
HP
office will arrange
for repair or replacement
without waiting for claim settlement.
2-5. PREPARATION
FOR USE.
2-6. POWER
REQUIREMENTS.
2-7.
The
4262A
requires
a power
source
of 100,
120, 220Volts ac +10%, or 240Volts ac +5%,-10%,
48 to 66Hz single
phase.
Power
consumption
is
approximately 55 watts.
WARNING
IF THIS INSTRUMENT
IS TO BE
ENERGIZED
VIA
AN
EXTER-
NAL AUTOTRANSFORMER
FOR
VOLTAGE
REDUCTION,
BE
SURE
THAT
THE
COMMON
TERMINAL
IS CONNECTED
TO
THE
NEUTRAL
POLE
OF
THE
POWER SUPPLY.
2-8.
LINE
VOLTAGE
AND
FUSE
SELECTION.
CAUTION
BEFORE
TURNING
THE
4262A
LINE
SWITCH
TO
ON,
VERIFY
THAT THE INSTRUMENT IS SET
TO
THE
VOLTAGE
OF
THE
POWER SUPPLIED.
2-9.
Figure
2-1 provides instructions for line volt-
age
and fuse selection.
The line voltage
selection
card and the proper fuse are factory installed for
the voltage appropriate to instrument destination.
CAUTION
USE
PROPER
FUSE
FOR
LINE
VOLTAGE SELECTED.
CAUTION
MAKE SURE THAT ONLY FUSES
FOR
THE
REQUIRED
RATED
CURRENT
AND
OF THE
SPECI-
FIED
TYPE ARE USED FOR RE-
PLACEMENT.
THE
USE
OF
MENDED
FUSES
AND
THE
SHORT-CIRCUITING
OF
FUSE-
HOLDERS
MUST
BE
AVOIDED.
2-10.
POWER CABLE.
2-11.
To
protect
operating
personnel,
the
2-1

Advertisement

Table of Contents
loading