Solution System

SOLENOID VALVE DISASSEMBLY AND CLEANING

1
Remove the solenoid valve. See the Solenoid Valve Removal section for instructions.
2
See Figure 3. Remove the (4) (I) Screws and disassemble the valve (be careful not to lose any internal parts).
3
Thoroughly wash dirt from block (J) and diaphragm (K).
4
After reassembling, test the solenoid valve for proper operation.

DISC MACHINE SOLUTION PLUMBING DETAIL

Top of Hose (L) uses a .109" diameter hole in the center. This prevents unbalanced solution flow.
FIGURE 4