Solution Solenoid Valve Disassembly And Cleaning; Solution Flow Control Valve Removal - Nilfisk-Advance 56397010 Service Manual

Table of Contents

Advertisement

SOLENOID VALVE DISASSEMBLY AND CLEANING
1
Remove the solenoid valve. See the Solution Solenoid Valve And Strainer Removal section for instructions.
2
See Figure 5. Remove the (2) (J) Screws and nuts and disassemble the valve (be careful not to lose any internal parts).
3
Thoroughly wash dirt from block (K) and diaphragm (L).
4
After reassembling, test the solenoid valve for proper operation.
Note: Solenoid valve replacement seal kit (Viton) part number 56324247.
FIGURE 5

SOLUTION FLOW CONTROL VALVE REMOVAL

1
Drain the solution tank and also remove the squeegee tool from the machine (this allows the needed room to work on the valve).
2
See Figure 4. Loosen the Hose Clamp (D) and pull the Hose (E) off the valve elbow fitting (F).
3
Remove the Screw (M) that holds together both the water valve shaft arm and the solution valve arm.
4
Separate the control arms and work the shaft up and off the valve to allow the clearance for removal.
5
Turn the valve out of the solution tank connection and remove it from the machine. Note it is not necessary to remove the tank drain hose, just compress
the hose to allow needed clearance to remove the valve.
J
L
FRONT
J
revised 9/01
FORM NO. 56043056 ConvertaMAX™ 20/26 / BA 550/650 - 19
SOLUTION SYSTEM
K

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents