Solution Solenoid Valve Disassembly And Cleaning - Nilfisk-Advance BA 1000 Service Manual

Table of Contents

Advertisement

______________________________________________________________________________________________

SOLUTION SOLENOID VALVE DISASSEMBLY AND CLEANING

1
Remove the solenoid valve (do not remove the fittings from the solenoid valve unless you are replacing the valve!).
Refer to the Solution Solenoid Valve Removal sections of this chapter.
2
See Figure 10. Remove the (2) (KK) Screws and Nuts and disassemble the valve (be careful not to lose any internal
parts).
LL
KK
3
Thoroughly wash any dirt from Block (LL) and Diaphragm (MM).
4
Reassemble in reverse order and test for leaks and proper operation.
MM
FORM NO. 56043025 / BA 700, 800, 1000 / 28LX, 32LX, 38LX / 280HD, 320HD, 380HD - 17
FIGURE 10
SOLUTION SYSTEM