• FQXSPBR4007I: Management Controller [arg1]: Configuration restoration from a file by user [arg2]
failed to complete.
This message is for the use case where a user restores a Management Controller configuration from a file
and the restoration fails to complete.
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0137
User Action:
Complete the following steps until the problem is solved:
1. Turn off the server and disconnect it from the power source. You must disconnect the server from AC
power cycle to reset the XCC.
2. After 45 seconds, reconnect the server to the power source and turn on the server.
3. Retry the operation.
• FQXSPBR4008I: Management Controller [arg1]: Configuration restoration from a file by user [arg2]
failed to start.
This message is for the use case where a user restores a Management Controller configuration from a file
and the restoration fails to start.
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0138
User Action:
Complete the following steps until the problem is solved:
1. Turn off the server and disconnect it from the power source. You must disconnect the server from AC
power cycle to reset the XCC.
2. After 45 seconds, reconnect the server to the power source and turn on the server.
3. Retry the operation.
• FQXSPCA0002M: Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted.
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has asserted.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Fan Failure
SNMP Trap ID: 11
CIM Prefix: PLAT CIM ID: 0480
User Action:
Complete the following steps:
24
ThinkSystem SE350 and ThinkSystem SE350 Enclosures Messages and Codes Reference