Lenovo 7Z46 Manual page 143

Enclosures. messages and codes reference
Hide thumbs Also See for 7Z46:
Table of Contents

Advertisement

Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFMA0029I: The PFA of DIMM [arg1] has been deasserted after applying PPR for this DIMM.
[arg2]
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0047M: SPD CRC checking failed on DIMM [arg1]. [arg2]
Severity: Warning
User Action:
Complete the following steps:
1. Perform a virtual reseat or AC cycle the server.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFPU0001N: An unsupported processor has been detected.
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo Support site for a firmware update required for this processor and install that update,
if applicable.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFPU0002N: An invalid processor type has been detected.
Severity: Error
User Action:
Complete the following steps:
1. Verify that the processor is a valid option that is listed as a Server Proven device for this system. If a
non-supported processor is identified, remove that processor or replace with a supported processor.
2. Check Lenovo Support site for a firmware update required for this processor and install that update,
if applicable.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFPU0003K: A processor mismatch has been detected between one or more processors in the
system.
Severity: Error
User Action:
Complete the following steps:
.
139
Chapter 3
UEFI events

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem se3507d1x7d277d1r

Table of Contents