Operation - Makita AN451 Instruction Manual

Pneumatic roofing coil nailer
Hide thumbs Also See for AN451:
Table of Contents

Advertisement

OPERATION

1
2
1
1. Small rod
2. Ejection port
10
CAUTION:
Make sure all safety systems are in working order before
operation.
1. To drive a nail, you may place the contact element
005632
against the workpiece and pull the trigger, or
2. Pull the trigger first and then place the contact element
against the workpiece.
No. 1 method is for intermittent nailing, when you wish to
drive a nail carefully and very accurately. No. 2 method is
for continuous nailing.
CAUTION:
005633
Operating the tool without nails shortens the life of the
tool and should be avoided.
Jammed nailer
005634
CAUTION:
Always disconnect the air hose and remove the nails
2
from the magazine before cleaning a jam.
When the nailer becomes jammed, do as follows:
Open the magazine cap and remove the nail coil. Insert a
small rod or the like into the ejection port and tap it with a
hammer to drive out the nail jamming from the ejection port.
Reset the nail coil and close the magazine cap.
Nails
004310
Handle nail coils and their box carefully. If the nail coils have
been handled roughly, they may be out of shape or their con-
nector breaks, causing poor nail feed.