To Remove The Accessories From The Outdoor Unit; Unit Installation; Preparing The Installation Site; Installation Site Requirements Of The Outdoor Unit - Daikin RXP20M5V1B Installation Manual

Hide thumbs Also See for RXP20M5V1B:
Table of Contents

Advertisement

4 Unit installation

1
2
3.1.2
To remove the accessories from the
outdoor unit
a
b
c
d
a
General safety precautions
b
Outdoor unit installation manual
c
Fluorinated greenhouse gases label
d
Multilingual fluorinated greenhouse gases label
e
Drain plug (located on the bottom of the packing case)
4
Unit installation
4.1

Preparing the installation site

WARNING
The appliance shall be stored in a room without
continuously operating ignition sources (example: open
flames, an operating gas appliance or an operating electric
heater).
4.1.1
Installation site requirements of the
outdoor unit
Mind the following spacing guidelines:
>150
>300
b
a
(mm)
a
Air outlet
b
Air inlet
Installation manual
6
e
b
>150
a
>50
(mm)
It is recommended to install a baffle plate when the air outlet is
exposed to wind.
It is recommended to install the outdoor unit with the air inlet facing
the wall and NOT directly exposed to the wind.
b
a
Baffle plate
b
Prevailing wind direction
c
Air outlet
4.1.2
Additional installation site requirements
of the outdoor unit in cold climates
Protect the outdoor unit against direct snowfall and take care that the
outdoor unit is NEVER snowed up.
c
a
Snow cover or shed
b
Pedestal
c
Prevailing wind direction
d
Air outlet
In any case, provide at least 300  mm of free space below the unit.
Additionally, make sure the unit is positioned at least 100 mm above
the maximum expected level of snow. See
unit" [ 4  7] for more details.
outdoor
In heavy snowfall areas it is very important to select an installation
site where the snow will NOT affect the unit. If lateral snowfall is
possible, make sure that the heat exchanger coil is NOT affected by
the snow. If necessary, install a snow cover or shed and a pedestal.
4.2

Opening the units

4.2.1

To open the outdoor unit

DANGER: RISK OF ELECTROCUTION
b
a
a
c
b
"4.3  Mounting the
(A)RXP20~35M5V1B
R32 split series
3P650253-6E – 2022.04

Hide quick links:

Advertisement

Table of Contents
loading