Timer

The timer can be set for periods of up to 99 minutes. It is
independent of the other settings. The hob must be switched
on. The timer can be set for any hotplate not turned on. This
function does not automatically switch off a hotplate.
How to program
Press the symbol
for the hotplate, the indicator
0
1.
turned on.
lights up in the time program function display.
‹‹
Select the desired time in the programming panel.
2.
The timer starts to count down after a few seconds.

Automatic time limitation

If the hotplate remains in use for a long time and no changes
are made in the settings, the automatic time limitation function
is triggered.
The hotplate stops heating. The
heat indicator
/
flash alternatively in the display.
œ

Cleaning lock function

Cleaning the control panel while the hob is on may change the
settings.
In order to avoid this, the hob has a cleaning lock function.
Press the
#
symbol. A signal sounds. The control panel is

Basic settings

The device has several basic settings. These settings may be
adapted to the user's individual needs.
Indicator
Function
Childproof lock
™‚
Deactivated.*
Activated.
™ƒ
Sound signals
Confirmation beep and error signal deactivated.
Only confirmation beep deactivated.
ƒ
All signals activated.*
Automatic timer
™†
Switched off.*
-
ŠŠ
Automatic shut-off time
Duration of the time program function warning signal
™‡
10 seconds*.
ƒ
30 seconds.
1 minute.
*Factory settings
is
W
symbol and the residual
"‰
Once the time has elapsed
A warning beep sounds. In the time program function
display
is shown, and the
‹‹
After 10 seconds the indicators turn off.
Pressing the
symbol turns off the indicators and stops the
0
beep.
Changing or cancelling the time
Press the
symbol of the desired hotplate. Change the
0
cooking time in the programming panel, or set to
Note: When the timer is activated, the corresponding hotplate
is locked. First turn off the timer and then the hotplate.
The indicator goes out when any symbol is pressed. The
hotplate can now be reset.
When the automatic time function is used, it is governed by the
selected power level (from 1 to 10 hours).
locked for 35 seconds. The surface of the control panel can
now be cleaned without risk of changing the settings.
Note: The lock does not affect the main switch. The hob may
be switched off when desired.