Model IFP-2000/ECS Installation Manual
Section 1

Introduction

The IFP-2000 Fire Alarm Control/Communicator is an analog addressable fire control system that meets the
requirements of UL 864. The RPS-2000 is used in a networked system where there is at least one IFP-2000 in the
system. The RPS-2000 is the same as the IFP-2000 without the display. When using the RPS-2000 as a stand
alone local unit, one RA-2000 must be connected, and the RA-2000 must be wired in conduit within 20' of the
RPS-2000.
The IFP-2000ECS Fire Alarm Control/Communicator is an analog addressable fire control system combined
with an Emergency Communication System that meets the requirements of UL standard 2572.
1.1

Overview of Basic System

The IFP-2000 base system is packaged as an assembled stack of 3 circuit boards mounted to an aluminum
housing.
1.1.1

Hardware Features

The basic IFP-2000 panel contains one built in signaling line circuit (SLC), which supports up to 159 IDP
sensors and 159 IDP modules or 127 SD SLC devices. Additional SLC loops can be added using the model
5815XL SLC expander to increase overall point capacity to a maximum of 636 points. The SLC(s) supports
both the SD Protocol and Intelligent Device Protocol (IDP).
Each SLC supports 159 IDP sensors and 159 IDP modules or 127 SD devices to a maximum of 636 points
per IFP-2000 control panel.
9.0A of output power is available through 8 sets of terminals for notification and auxiliary applications.
Each circuit is power limited per UL 864 and can source up to 3.0A (total output power must not exceed
9.0A). The constant auxiliary power load must not exceed 6.0A for normal standby.
Built-in dual phone line, digital alarm communicator/transmitter (DACT).
Reports events to central station by point or by zone.
UL Listed for pre-action and deluge releasing systems.
Dedicated Form C trouble relay and two general purpose Form C programmable relays.
Can be used with Model RA-2000 remote annunciators (sold separately).
Supports the 5865-3, 5865-4, and 5880 LED annunciators. See sections 4.8 and 4.9 for additional
information on these models (sold separately).
Printing of event log available through the Model 5824 serial/parallel printer interface module (sold
separately).
Supports conventional 2-wire & 4-wire detectors using the 8 Flexput™ circuits or SLC zone modules.
999 software zones, 999 output groups.
Add four notification/auxiliary power circuits with each 5496 Intelligent Power Module.
Add six Flexput™ circuits with each RPS-1000 Remote Power Supply.
Interconnection capability for up to eight panels.
1.1.2

Network System Hardware Features

The default network setup can contain up to eight IFP-2000 / RPS-2000 panels connected within a
networked system providing a maximum addressable point capacity of 5,088.
The networked system can be configured to emulate a large virtual system or can be segmented into separate